KVH Industries TracVision M5 用户手册

下载
页码 41
6
Once you have identified suitable mounting sites 
for the switchplate and MCP, follow these steps 
to prepare the sites for installation.
Switchplate
a. Using the switchplate mounting template 
provided at the end of this manual, mark and 
cut out a hole in the mounting surface to 
accommodate the switchplate (see Figure 7). 
b. Using the same template, mark the locations 
for the four switchplate mounting holes. 
c. Drill a 3/32" (2.25 mm) hole at the four 
mounting hole locations. Later, you will 
mount the switchplate using four #6 screws.
MCP (Flush Mount only)
NOTE: Skip this step if you plan to mount the MCP 
to a horizontal surface instead.
a. Attach the supplied flush mount bracket to 
the MCP now, before you connect any cables. 
Simply slide the bracket onto the MCP from 
behind and position the front edge of the 
bracket over the seam line between the front 
bezel and the chassis. Secure the bracket in 
place using two #6-32 screws and washers 
b. Using the MCP flush mounting template 
provided at the end of this manual, mark and 
cut out a hole in the mounting surface to 
accommodate the flush mount bracket (see 
c. Using the same template, mark the locations 
for the four MCP mounting holes.
d. Using a #29 drill bit, drill a 0.136" (3.45 mm) 
hole at the four mounting hole locations. 
Later, you will mount the MCP using four #8 
screws.
  3/32" (  2.25 mm)
Mounting Hole (x4)
3.82"
(97 mm)
.32" (8 mm)
2.36"
(60 mm)
.16" (4 mm)
3.19"
(81 mm)
2.05"
(52 mm)
Panel Cutout
Figure 7:  Switchplate Mounting Holes Layout
#6-32 x 1/2" Screw 
and Washer (x2)
Figure 8:  MCP Flush Mount Bracket
8.87"
(225 mm)
7.62"
(194 mm)
.63"
(16 mm)
3.08"
(78 mm)
1.83"
(46 mm)
.63"
(16 mm)
  .136" (  3.45 mm)
Mounting Hole (x4)
Figure 9:  MCP Mounting Holes Layout
Prepare the Belowdecks Sites
4