Operator’s Manual
Installation
INSTallaTION
In the U.S.A., this appliance must be installed in accordance with 
the local code and the relevant national code: 
aNSI z223.1-latest 
edition National fuel Gas Code 
In Canada, this appliance must be installed in accordance with the 
local code and the relevant CGA standards: 
CaN/CGa-B149.1 
Natural Gas Code and latest Local Codes where applicable. 
Grills are equipped with a quick disconnect coupler at the end of 
the hose.
Have a licensed gas personal install a natural gas outlet in location 
required according to the appropriate code listed above.
NOTe: The code requires a manual shut off valve controlling this 
outlet to be installed on the inside of the building.
The appliance must be located away from combustible surfaces by 
at least 30”/76cm from each side, and 30”/76cm from the rear. 
Do not operate this appliance under any overhead roof construction 
or foliage. 
This appliance is for 
OuTdOOR uSe ONlydO NOT operate in 
garage, shed, balcony or other such enclosed areas. 
dO NOT restrict the flow of air to the appliance. 
Keep  the  area  surrounding  the  appliance  free  of  combustible 
materials, gasoline, and all flammable liquids and vapors. 
This appliance is not intended to be installed in, or on, recreational 
vehicles and/or boats. 
30” / 76cm
30” / 76cm