Motorola GT10 用户手册

下载
页码 195
GT10/GT30
5.3
Entering Configuration Settings from the GT10
87
Procedure for bringing up the screen
[Initial screen]
[Setting]
[TOOL Port]
Through function: Through function destination setting
When the through function is being used, this specifies the number of the PLC at the
other end of the connection. Normally, when used in a 1 : 1 configuration, this should
be set to “00”.
Bitrate: GTWIN communication speed
Each time the [Function] key is touched, the Baud rate switches in the sequence of
9600/19200/115200 bits/s. Set the speed to match that of the personal computer
(GTWIN) connected to the GT10.
Format: Transmission format
This sets the communication parameters (data length, stop bits, parity) for the personal
computer (GTWIN) connected to the GT10.
The items displayed are: Data length / Stop bit / Parity, and each time the [Function] key
is pressed, the display switches in the sequence of: [8/1/None], [8/1/Odd], [8/1/Even].
SHORTCUTS
[RETURN]To complete the settings and return to the previous screen, 
touch the [ESC] key.
EXPLANATION
TOOL Port communication parameter settings
The default (initial) values for the TOOL Port communication
parameter settings are: 19200 bits/s, 8/1/Odd.
5.3.4
Setting Mode: “Liquid Crystal Display Contrast Adjustment”
(Contrast)
Touching [Setting] on the initial screen of the system menu and then the [Contrast] key
of the setting mode menu displays the contrast adjustment screen. The contrast of the
GT10 LCD is adjusted here.
Contrast adjustment screen
Procedure for bringing up the screen
[Initial screen]
[Setting]