4. HOW TO MONITOR REDUNTANT SYSTEM
4.1 Connection to Remote I/O Station in MELSECNET/H Network System
4 - 9
1
P
R
EP
ARA
T
OR
Y
 
P
R
OCEDURES FOR 
MONIT
O
R
ING
2
DE
VICE RA
NGE 
THA
T
 C
A
B
E
 SET
3
ACCESS
 RANGE 
F
O
R MONIT
O
RING
4
HOW T
O
 MONIT
O
REDUNT
ANT 
SYS
TE
M
5
BUS CONNECTION
6
DIRE
CT
 
CONNECTION T
O
 
CPU
7
COMP
U
T
E
R
 LINK 
CONNECTION
8
ETHERNE
T
 
CONNE
C
T
ION
4.1.2
Computer link connection (Connection to serial communication module 
mounted on remote I/O station)
This section explains the computer link connection that connects the GOT to the serial communication module mounted 
on the remote I/O station of the MELSECNET/H network system.
The following shows an example of connecting the GOT to the serial communication module mounted on the remote I/O 
station of the MELSECNET/H network system.
(1) Connection method
Connect the GOT to the serial communication module (QJ71C24, QJ71C24-R2, QJ71C24N, QJ71C24N-R2, 
QJ71C24N-R4) or modem interface module (QJ71CM0) mounted on the remote I/ O station of the 
MELSECNET/H network system.
For details, refer to the following.
(2) GT Designer3 setting
Set GT Designer3 as follows.
In this case, the GOT monitoring is performed by transient transmission of the MELSECNET/H network system. 
Therefore, a longer time-lag occurs for displaying objects compared with directly monitoring the PLC CPU.
For displaying objects with a shorter time-lag, execute the cyclic transmission so that the GOT can monitor link 
devices B and W of the host station set in the MELSECNET/H network.
For details, refer to the following manual.
Q Corresponding MELSECNET/H Network System Reference Manual (Remote I/Q network)
(3) Monitoring target change when system switching occurs in a redundant system
When the system switching occurs, the multiplexed remote sub master station switched to the control system 
takes over the master operation of MELSECNET/H.
Since the GOT monitors the master station, the monitoring target is automatically changed to the PLC CPU that 
is operating as the master.
Setting item
Settings
Model
Controller Type
MELSEC-QnA/Q/QS, MELDAS C6*
MELSEC-QnA/Q, MELDAS C6*
Device setting
(Network setting)
Host
Host
Remote master 
station
Other (NW No. 1 (network No. of remote I/O network), 
Station No. 0 (master station))
Q Redundant Setting
Do not set the item.
Monitor target
MELSECNET/H remote I/O network
Computer link connection
GOT
Network No. 1, Station No. 0
(Multiplexed remote master station)
Q25PRHCPU
QJ71LP21-25
QJ71BR1
1
QJ71E71-100
QJ61BT1
1N
Network No. 1, Station No. 1
(Multiplexed remote sub master station)
Standby system
(System B)
Q25PRHCPU
QJ71LP21-25
QJ71BR1
1
QJ71E71-100
QJ61BT1
1N
QJ72LP25-25
QJ71C24N
Network No. 1, Station No. 2
(Remote I/O station)
Empty
Empty
Empty
Empty
Power
supply module
Power
supply module
Power
supply module
Control system
(System A)