Mitsubishi Electronics Mitsubishi Digital Electronics Portable Multimedia Player GOT1000 用户手册

下载
页码 754
8. ETHERNET CONNECTION
8.2 System Configuration
8 - 11
1
P
R
EP
ARA
T
OR
Y
 
P
R
OCEDURES FOR 
MONIT
O
R
ING
2
DE
VICE RA
NGE 
THA
T
 C
A
B
E
 SET
3
ACCESS
 RANGE 
F
O
R MONIT
O
RING
4
HOW T
O
 MONIT
O
REDUNT
ANT 
SYS
TE
M
5
BUS CONNECTION
6
DIRE
CT
 
CONNECTION T
O
 
CPU
7
COMP
U
T
E
R
 LINK 
CONNECTION
8
ETHERNE
T
 
CONNE
C
T
ION
8.2.2
Connection to Built-in Ethernet port CPU or C Controller module
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network 
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
*2
A straight cable is available.
When connecting QnUDE(H) and GOT directly with Ethernet cable, connection by cross cable is available.
*3
When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching 
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
GT16 User's Manual (Hardware)
*4
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of 
cascades.
For the limit, contact the switching hub manufacturer.
*5
For the system configuration of Built-in Ethernet port QCPU, refer to the following manual.
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
*6
Select [QnUDE(H)] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*7
For the system configuration of Built-in Ethernet port LCPU, refer to the following manual.
MELSEC-L CPU Module User's Manual (Built-In Ethernet Function)
*8
Select [LCPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*9
GT14 models compatible with Ethernet connection are only GT1455-QTBDE and GT1450-QLBDE.
Ethernet(MELSEC),Q17nNC,CRnD-700
Communication driver
Connecting to
Built-in
Ethernet port
CPU
GOT
Connection cable
PLC
Connection cable
*1*2
Maximum 
segment 
length
*4
GOT
Number of 
connectable 
equipment
Model name
Communication 
type
Option device
Model
MELSEC-QnUDE(H)
*5*6
Ethernet
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable (STP) or 
unshielded twisted pair cable (UTP): 
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair cable (STP): 
Category 5 and 5e
100m
- (Built into GOT)
*3
*9
16 GOTs
GT15-J71E71-100
C Controller module
Ethernet
100m
- (Built into GOT)
*3
*9
16 GOTs
GT15-J71E71-100
MELSEC-L
*7*8
Ethernet
100m
- (Built into GOT)
*3
*9
16 GOTs
GT15-J71E71-100