Mitsubishi Electronics Mitsubishi Digital Electronics Portable Multimedia Player GOT1000 用户手册
8. ETHERNET CONNECTION
8.4 PLC Side Setting
8 - 27
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES FOR
MONIT
O
R
ING
2
DE
VICE RA
NGE
THA
T
C
A
N
B
E
SET
3
ACCESS
RANGE
F
O
R MONIT
O
RING
4
HOW T
O
MONIT
O
R
REDUNT
ANT
SYS
TE
M
5
BUS CONNECTION
6
DIRE
CT
CONNECTION T
O
CPU
7
COMP
U
T
E
R
LINK
CONNECTION
8
ETHERNE
T
CONNE
C
T
ION
Confirming the communication state of
Ethernet module
Ethernet module
(1) When using the Command Prompt of Windows
.
Execute a Ping command at the Command Prompt of
Windows
Windows
.
(a) When normal communication
C:\>Ping 192.168.0.19
Reply from 192.168.0.19: bytes=32 time<1ms
TTL=64
Reply from 192.168.0.19: bytes=32 time<1ms
TTL=64
(b) When abnormal communication
C:\>Ping 192.168.0.19
Request timed out.
Request timed out.
(2) When abnormal communication
At abnormal communication, check the followings and
execute the Ping command again.
• Mounting condition of Ethernet communication unit
• Cable connecting condition
• Confirmation of switch and network parameter setting
• Operation state of PLC CPU (faulty or not)
• IP address of GOT specified by Ping command
execute the Ping command again.
• Mounting condition of Ethernet communication unit
• Cable connecting condition
• Confirmation of switch and network parameter setting
• Operation state of PLC CPU (faulty or not)
• IP address of GOT specified by Ping command
POINT
POINT
POINT
Ethernet diagnostics of GX Developer
Ethernet diagnostics of GX Developer is available to a
Ping test from the PLC.
For details of Ethernet diagnostics of GX Developer,
refer to the following manual.
Ethernet diagnostics of GX Developer is available to a
Ping test from the PLC.
For details of Ethernet diagnostics of GX Developer,
refer to the following manual.
User's manual of the Ethernet module
8.4.4
Connecting to C Controller
module
module
This section describes the settings of the GOT and C
Controller module in the following case of the system
configuration.
Controller module in the following case of the system
configuration.
POINT
POINT
POINT
C Controller module
For details of C Controller module, refer to the
following manual.
For details of C Controller module, refer to the
following manual.
C Controller Module User's Manual (Hardware
Design, Function Explanation)
Design, Function Explanation)
System configuration
*1
These setting items do not exist at the PLC side. However,
the virtual values must be set on the GOT side.
the virtual values must be set on the GOT side.
<GOT>
(The settings other than the
following are set to the default)
(The settings other than the
following are set to the default)
Network No.
: 1
PLC No.
: 1
IP address
: 192.168.3.18
Port No.
: 5001
Communication
format
format
: UDP(fixed)
Network No.
: 1 (virtual)
PLC No.
: 2 (virtual)
IP address
: 192.168.3.1
Port No.
: 5006(fixed)
Communication
format
format
: UDP(fixed)
<C controller module>
(The settings other than the
following are set to the default)
(The settings other than the
following are set to the default)
1
Network No.
: 1 (virtual)
PLC No.
: 3 (virtual)
IP address
: 192.168.3.2
Port No.
: 5006(fixed)
Communication
format
format
: UDP(fixed)
<C controller module>
(The settings other than the following are
set to the default)
(The settings other than the following are
set to the default)
2
*1
*1
*1
*1
■
■
■