(3) Communication confirmation
The RDY LED on the Ethernet module turn on when
the module is ready to communicate.
For confirming the communication state, refer to the
following.
the module is ready to communicate.
For confirming the communication state, refer to the
following.
[Controller Setting] and [Ethernet] of GT
Designer3
Designer3
(1) Controller setting
(2) Ethernet setting
POINT
POINT
POINT
[Controller Setting] and [Ethernet] of GT Designer3
For [Controller Setting] and [Ethernet] of GT
Designer3, refer to the following.
For [Controller Setting] and [Ethernet] of GT
Designer3, refer to the following.
8.4.6
Connecting to Ethernet
module (A Series)
module (A Series)
This section describes the settings of the GOT and
Ethernet module (A Series) in the following case of the
system configuration.
Ethernet module (A Series) in the following case of the
system configuration.
POINT
POINT
POINT
Ethernet module (A Series)
For details of the Ethernet module (A Series), refer to
the following manual.
For details of the Ethernet module (A Series), refer to
the following manual.
For A Ethernet Interface Module User’s Manual
System configuration
*1
The Ethernet module is mounted on the base unit slot 0.
The Start I/O No. of the Ethernet module is set to "0".
The Start I/O No. of the Ethernet module is set to "0".
*2
These setting items do not exist at the PLC side. However,
the virtual values must be set on the GOT side.
the virtual values must be set on the GOT side.
Item
Set value (Use default value)
GOT NET No.
1
GOT PLC No.
1
GOT IP Address
192.168.0.18
GOT Port No.
(Communication)
(Communication)
5001
GOT Port No.
(Ethernet Download)
(Ethernet Download)
5014
Default Gateway
0.0.0.0
Subnet Mask
255.255.255.0
Retry
3times
Startup Time
3sec
Timeout Time
3sec
Delay Time
0ms
Item
Set value
Ethernet
setting No.1
setting No.1
Host
*
N/W No.
1
PLC No.
2
Type
AJ71QE71
IP address
192.168.0.19
Port No.
5001 (fixed)
Communication
UDP (fixed)
RUN
BUF1
BUF2
BUF3
BUF4
BUF5
BUF6
BUF7
BUF8
BUF2
BUF3
BUF4
BUF5
BUF6
BUF7
BUF8
RDY
BSY
SW.ERR.
COM.ERR.
CPU R/W
TEST
TEST ERR.
BSY
SW.ERR.
COM.ERR.
CPU R/W
TEST ERR.
TEST
RDY
RUN
BUF1
BUF2
BUF3
BUF4
BUF5
BUF6
BUF7
BUF8
BUF2
BUF3
BUF4
BUF5
BUF6
BUF7
BUF8
A1SJ71QE71N3-T, A1SJ71QE71N-B5,
A1SJ71QE71N-B2, A1SJ71QE71N-T,
A1SJ71QE71N-B5T,A1SJ71QE71-B5,
A1SJ71QE71-B2
A1SJ71QE71N-B2, A1SJ71QE71N-T,
A1SJ71QE71N-B5T,A1SJ71QE71-B5,
A1SJ71QE71-B2
AJ71QE71N3-T, AJ71QE71N-B5,
AJ71QE71N-B2, AJ71QE71N-T,
AJ71QE71N-B5T, AJ71QE71,
AJ71QE71-B5
AJ71QE71N-B2, AJ71QE71N-T,
AJ71QE71N-B5T, AJ71QE71,
AJ71QE71-B5
<GOT> (The settings other than the
following are set to the default)
following are set to the default)
*2
*2
*1
Network No.
: 1
PLC No.
: 1
IP address
: 192.168.0.18
Port No.
: 5001
Communication format : UDP (fixed)
Network No.
: 1 (virtual)
PLC No.
: 2 (virtual)
IP address
: 192.168.0.19
Port No.
: 5001
Communication format
: UDP(fixed)
<Ethernet module> (The settings other than the
following are set to the default)
following are set to the default)
■