9. MELSECNET/H CONNECTION (PLC TO PLC NETWORK)
9.3 GOT Side Settings
*1
Cannot be set for the QCPU redundant system.
*2
For details, refer to the following manual.
 
Q corresponding MELSECNET/H Network System 
Reference Manual (PLC to PLC network)
POINT
POINT
POINT
(1) Communication interface setting by Utility
The communication interface setting can be 
changed on the Utility's [Communication Settings] 
after writing [Communication Settings] of project 
data.
For details on the RS-422 conversion unit and the 
GOT utility, refer to the following manual:
GT  User's Manual
(2) Precedence in communication settings
When settings are made by GT Designer3 or the 
Utility, the latest setting is effective.
9.3.3
Routing parameter setting
Up to 64 [Transfer Network No.]s can be set.
However, the same transfer network number cannot be set 
twice or more (multiple times).
Therefore, the one that can access to other station from the 
request source host GOT is 64 kinds of [Transfer Network 
No.]s.
POINT
POINT
POINT
Routing parameter setting
When communicating within the host network, routing
parameter setting is unnecessary.
For details of routing parameters, refer to the following
manual.
Q corresponding MELSECNET/H Network 
System Reference Manual (PLC to PLC 
network)
POINT
POINT
POINT
(1) Routing parameter setting of relay station
Routing parameter setting is also necessary for 
the relay station.
For the setting, refer to the following.
(2) Parameter reflection function of MELSOFT Navigator
(a) The color of the cells for the items which are 
reflected to GT Designer3 from MELSOFT 
Navigator changes to green. Set items, which 
are displayed in green cells, from the 
MELSOFT Navigator.
(b) When the settings of Transfer network No., 
Relay network No. or Relay station No. are 
reflected to the parameter from the MELSOFT 
Navigator, those settings are added. Items set 
in advance are not deleted.However, if the 
target network No. overlaps, the item set in 
advance is overwritten.
(c) The routing information is used manually by 
the user when the data is created. Therefore, 
after changing the network configuration by 
MELSOFT Navigator, create a routing 
information again. For details of the creation 
of the routing information, refer to the 
MELSOFT Navigator help.
Refresh 
Interval
Set the number of refreshes to 
secure the send/receive data in 
station units during 
communication.
(Default: 1time)
Valid when [Secured data send/
Secured data receive] Is marked 
by the control station side network 
parameters of the melsecnet/h 
network system.
1 to 1000times
Transmission 
Speed
Set the communication 
transmission speed.
(Default: 25Mbps)
When specifying [MNET/10 
mode] as The network type, only 
10mbps can be set applicable.
10Mbps/25Mbps
Item
Description
Range
Item
Range
Transfer Network No.
1 to 239
Relay Network No.
1 to 239
Relay Station No.
1 to 64