13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
13.4 PLC Side Setting
13 - 31
9
ME
LSECNE
T
/H
CONN
E
CT
ION (P
LC
T
O
P
L
C NE
T
W
ORK)
10
ME
LSE
C
N
E
T/10
CONNECTION
(P
LC
T
O
P
LC NE
T
W
ORK)
11
CC
-Lin
k I
E
C
O
N
TRO
LL
E
R
NE
TW
ORK
C
O
NNE
CT
IO
N
12
CC-Lin
k IE FIELD
NETW
ORK
CONN
ECTION
13
CC
-Li
nk C
O
NN
ECTI
O
N
(INTELLIGEN
T
D
EVICE
ST
AT
IO
N)
14
CC-Lin
k
CONNECTION
(V
ia G4)
15
IN
VER
TER
CONNECTION
16
SE
R
V
O AMP
LI
F
IE
R
CONNE
C
T
ION
[Controller Setting] of GT Designer3
(1) When MODEL GT15-J61BT13 CC-Link
communication unit is used
(2) When MODEL GT15-75J61BT13-Z CC-Link
communication unit is used
POINT
POINT
POINT
[Controller Setting] of GT Designer3
For the setting method of [Controller Setting] of GT
Designer3, refer to the following.
For the setting method of [Controller Setting] of GT
Designer3, refer to the following.
Setting of the CC-Link communication unit
(Only when MODEL GT15-75J61BT13-Z
CC-Link communication unit is used)
(Only when MODEL GT15-75J61BT13-Z
CC-Link communication unit is used)
POINT
POINT
POINT
Setting of the CC-Link communication unit
For the setting method of the CC-Link communication
unit, refer to the following.
For the setting method of the CC-Link communication
unit, refer to the following.
13.4.7 Connecting to CC-Link module
(A Series)
This section describes the settings of the GOT and CC-
Link module (A Series) in the following case of system
configuration.
Link module (A Series) in the following case of system
configuration.
POINT
POINT
POINT
CC-Link module (A Series)
For details of the CC-Link module (A Series), refer to
the following manual.
For details of the CC-Link module (A Series), refer to
the following manual.
Control & Communication Link System Master/
Local Module Type AJ61BT11/A1SJ61BT11
User's Manual
Local Module Type AJ61BT11/A1SJ61BT11
User's Manual
System configuration
*1
The CC-Link module is mounted on the base unit slot 0.
The Start I/O No. of the CC-Link module is set to "0"
The Start I/O No. of the CC-Link module is set to "0"
Item
Set value
Station No.
1: Station No.1
Transmission Rate
0: Online 156kbps
Mode
Ver.1: Remote net (Ver.1 mode)
Expanded Cyclic
Single (Use default value)
Number of stations occupied
1 Station
Input for Error Station
0: Clear
Retry
3times (Use default value)
Timeout Time
3sec (Use default value)
Delay Time
0ms (Use default value)
Item
Set value (Use default value)
Retry
3times
Timeout Time
3sec
Item
Set value
Mode setting switch
0: Online (fixed)
Station number setting switch
1: Station No.1
Transmission baudrate setting switch
0: 156kbps
Condition
setting
switches
setting
switches
SW1
(Input data status of the data
link error station)
(Input data status of the data
link error station)
OFF: Cleared
SW2 (Number of occupied
stations)
stations)
OFF: 1 station
*1
<CC-Link module>
(Use the default value for settings other than the following.)
(Use the default value for settings other than the following.)
<GOT>
(Use the default value for settings other
than the following.)
(Use the default value for settings other
than the following.)
Station type
: Master station
All connect count
: 1
Mode setting
: Remote net mode
Station No.
: Station No.0
Module mode
: Intelligent mode
Transmission speed : 156kbps
Station type
: Intelligent device
station
station
Station No.
: Station No.1
Number of station occupied : Exclusive station 1
Transmission
speed
Transmission
speed
: 156kbps