Mitsubishi Electronics Mitsubishi Digital Electronics Portable Multimedia Player GOT1000 用户手册

下载
页码 754
15. INVERTER CONNECTION
15.4 GOT Side Settings
15 - 29
9
ME
LSECNE
T
/H 
CONN
E
CT
ION (P
LC 
T
O
 P
L
C NE
T
W
ORK)
10
ME
LSE
C
N
E
T/10
 
CONNECTION
 (P
LC 
T
O
 P
LC NE
T
W
ORK)
11
CC
-Lin
k I
E
 C
O
N
TRO
LL
E
NE
TW
ORK
 
C
O
NNE
CT
IO
N
12
CC-Lin
k IE FIELD 
NETW
ORK 
CONN
ECTION
13
CC-
Li
nk
 CONNECTI
O
(INTEL
LI
G
E
NT
 DEVI
CE 
ST
AT
IO
N)
14
CC-Lin
CONNECTION  (V
ia G4)
15
IN
VER
TER 
CONNECTION
16
SE
R
V
O AMP
LI
F
IE
CONNE
C
T
ION
15.4 GOT Side Settings
15.4.1 Setting communication 
interface (Communication 
settings)
Set the channel of the connected equipment.
1.
Select [Common] 
 [Controller Setting] from the 
menu.
2.
The Controller Setting window is displayed. Select the 
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: Mitsubishi
• Controller Type: Set according to the Controller 
Type to be connected.
• I/F: Interface to be used
• Driver: FREQROL 500/700
4.
The detailed setting is displayed after Manufacturer, 
Controller Type, I/F, and Driver are set.
Make the settings according to the usage 
environment.
Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be 
confirmed in [I/F Communication Setting].
For details, refer to the following.
15.4.2 Communication detail settings
Make the settings according to the usage environment.
POINT
POINT
POINT
(1) Communication interface setting by the Utility
The communication interface setting can be 
changed on the Utility's [Communication Settings] 
after writing [Communication Settings] of project 
data.
For details on the Utility, refer to the following 
manuals.
GT  User's Manual
(2) Precedence in communication settings
When settings are made by GT Designer3 or the 
Utility, the latest setting is effective.
2.
3.
4.
Click!
Item
Description
Range
Transmission 
Speed
Set this item when change the 
transmission speed used for 
communication with the 
connected equipment.
(Default: 19200bps)
9600bps,
19200bps,
38400bps,
57600bps,
115200bps
Data Bit
Set this item when change the 
data length used for 
communication with the 
connected equipment.
(Default: 7bits)
7bits/8bits
Stop Bit
Specify the stop bit length for 
communications.
(Default: 1bit)
1bit/2bits
Parity
Specify whether or not to perform 
a parity check, and how it is 
performed during communication.
(Default: Odd)
None
Even
Odd
Retry
Set the number of retries to be 
performed when a communication 
timeout occurs.
(Default: 0time)
0 to 5times
Timeout Time
Set the time period for a 
communication to time out.
(Default: 3sec)
1 to 30sec
Delay Time
Set this item to adjust the 
transmission timing of the 
communication request from the 
GOT.
(Default: 10ms)
0 to 300ms