Mitsubishi Electronics Mitsubishi Digital Electronics Portable Multimedia Player GOT1000 用户手册
15. INVERTER CONNECTION
15.5 FREQROL Series Inverter Side Settings
15 - 37
9
ME
LSECNE
T
/H
CONN
E
CT
ION (P
LC
T
O
P
L
C NE
T
W
ORK)
10
ME
LSE
C
N
E
T/10
CONNECTION
(P
LC
T
O
P
LC NE
T
W
ORK)
11
CC
-Lin
k I
E
C
O
N
TRO
LL
E
R
NE
TW
ORK
C
O
NNE
CT
IO
N
12
CC-Lin
k IE FIELD
NETW
ORK
CONN
ECTION
13
CC-
Li
nk
CONNECTI
O
N
(INTEL
LI
G
E
NT
DEVI
CE
ST
AT
IO
N)
14
CC-Lin
k
CONNECTION (V
ia G4)
15
IN
VER
TER
CONNECTION
16
SE
R
V
O AMP
LI
F
IE
R
CONNE
C
T
ION
15.5.7 Connecting FREQROL-D700 series
Communication settings
Make the communication settings of the inverter.
Be sure to perform the inverter reset after updating each parameter.
Be sure to perform the inverter reset after updating each parameter.
(1) Communication port and corresponding parameters
(2) Communication settings of inverter
Set the following parameters using the PU (parameter unit). Set Pr.160 (User group read selection) to 0 [The
simple mode and extended parameters can be displayed] before making the parameter settings.
Do not change these parameters, even though they can be monitored from the GOT. If they are changed,
communication with the GOT is disabled.
simple mode and extended parameters can be displayed] before making the parameter settings.
Do not change these parameters, even though they can be monitored from the GOT. If they are changed,
communication with the GOT is disabled.
*1
Setting items are parameter names described in the manual of FREQROL-D700 series.
*2
Settings on the GOT can be changed.
When changing the settings on the GOT, be sure to change the parameters on the inverter to correspond with the GOT settings.
When changing the settings on the GOT, be sure to change the parameters on the inverter to correspond with the GOT settings.
*3
Inverter default values (No need to change)
GOT connection
destination
Parameters corresponding to inverter
PU connector
Pr.79, Pr.117 to Pr.124, Pr.340, Pr.342, Pr.549
Setting item
*1
Parameter No.
Set value
Contents of setting
PU communication station number
Pr.117
0 to 31
PU communication speed
*2
Pr.118
192
*3
19200bps
PU communication stop bit length*2
Pr.119
10
Data length: 7bit
Stop bit length: 1bit
PU communication parity check
*2
Pr.120
1
Odd
Number of PU communication retries
Pr.121
9999
The inverter will not come to an
alarm stop.
PU communication check time interval
Pr.122
9999
Communication check
suspension
PU communication wait time setting
Pr.123
0
0ms
PU communication CR/LF selection
Pr.124
1
*3
With CR, without LF
Protocol selection
Pr.549
0
*3
Mitsubishi inverter protocol
Operation mode selection
Pr.79
0
*3
PU operation mode
Communication startup mode selection
Pr.340
1
Network operation mode.
Communication EEPROM write selection
Pr.342
0
*3
Written to RAM and EEPROM