15. INVERTER CONNECTION
15.6 Device Range that Can Be Set
15.6 Device Range that Can Be Set
The device ranges of controller that can be used for GOT 
are as follows.
Note that the device ranges in the following tables are the 
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ 
depending on the models, even though belonging to the 
same series.
Please make the setting according to the specifications of 
the controller actually used.
When a non-existent device or a device number outside 
the range is set, other objects with correct device settings 
may not be monitored.
Setting item
*1
The following shows the relation between the inverter station 
numbers and the GOT data register.
(1) Setting the device by inputting directly from the 
keyboard
When setting the device by inputting directly from the 
keyboard, set the items as follows.
Inverter (FREQROL 500/700 series)
*1
When creating the screen, designate only either of 
programmed operation (PG) device or parameter (Pr) 
device.
Do no designate both PG (PG0 to PG89) and Pr (Pr900 to 
Pr905) devices.
*2
Only 16-bit (1-word) designation is possible.
*3
Only reading is possible.
*4
Precautions for PU operation mode
When the GOT is connected to the PU connector and the 
operation mode is set to the PU operation mode, the multi-
speed operation (W3 to W7, SP121, SP122) cannot be used.
For using the multi-speed operation, follow either of the 
operations as below.
• Connect the GOT to the RS-485 terminal and set the 
operation mode to the NET operation mode (Computer 
link operation mode), and then operate the inverter.
• Change the motor speed with the set frequency (SP109, 
SP110), and then operate the inverter with the forward or 
reverse rotation (WS1, WS2, SP121, SP122).
*5
Precautions for WS devices
Only writing is possible for WS devices.
More than one WS cannot turn on at once.
(Except the turned on WS device, the other WS devices turn 
off.)
Bits of SP122 (word device) and SP121 (word device) are 
assigned to WS0 to WS7 and WS8 to WS15 respectively.
When more than one WS turns on at once, convert the 
values for the bit devices that are assigned to the word 
device into values for the word device. Write the converted 
values into SP122 or SP121.
• Setting High speed operation command (WS5), Middle 
speed operation command (WS4), and Low speed 
operation command (WS3)
When setting High speed operation command (WS5), 
Middle speed operation command (WS4), and Low speed 
operation command (WS3), write numerical values to 
device SP122 as necessary.
As the following figure shows, each operation mode is 
assigned to device SP122.
The following shows an example for Forward rotation 
command (WS1) and Low speed operation command 
(WS3).
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only by specifying the bit of word 
device.
Station 
No.
Monitors the inverter of the specified station No.
0 to 31: To monitor the inverter of the specified 
station No.
100 to 115: To specify the station No. of the inverter 
to be monitored by the value of GOT data register 
(GD).
*1
Information
Displays the device type and setting range which are 
selected in [Device].
Station 
No.
GOT data register (GD)
Setting range
100
GD10
0 to 31
(If setting a value 
outside the 
range above, a 
device range 
error occurs)
101
GD11
:
:
114
GD24
115
GD25
Station No.
Device number
Device name
Device name
Setting range
Device
No. 
represen
tation
B
it device
Inverter
status monitor
(RS)
*3
RS0: 0
 to 
RS15: 31
RS0: 100
 to 
RS15: 115
Decimal
Run command 
(WS)
*4*5
WS0: 0
 to 
RS15: 31
WS0: 100
 to 
RS15: 115
W
o
rd device
Alarm definition 
(A)
*2*3
A0: 0
 to 
A7: 31
A0: 100
 to 
A7: 115
Decimal
Parameter (Pr)
*1*2
Pr0: 0
 to 
Pr999: 31
Pr0: 100
 to 
Pr999: 115
Programmed 
operation
(PG)
*1*2
PG0: 0
 to 
PG89: 31
PG0: 100
 to 
PG89: 115
Special 
parameter
(SP)
*2*4
SP108: 0
 to 
SP127: 31
SP108: 100
 to 
SP127: 115