Mitsubishi Electronics Mitsubishi Digital Electronics Portable Multimedia Player GOT1000 用户手册
18. CNC CONNECTION
18.4 GOT Side Settings
18 - 13
17
ROBOT CONT
ROLLER
CONN
E
C
T
ION
18
CNC CONNECTION
19
GOT
MUL
T
I-
DROP
C
O
NNECTION
20
MUL
TIPLE-G
T14
, GT
12,
GT1
1, G
T10
C
O
NNEC
TI
O
N FUNCTIO
N
21
MUL
T
I-CHANNEL
FUN
C
TIO
N
22
F
A
TRANSP
A
R
E
N
T
FUNC
TION
18.4.3 Ethernet setting
*1
For operating CNC monitor function, set N/W No. to "239".
18.4.4 Switch setting
Switch setting (GT15-75J71P23-Z, GT15-
75JBR13-Z)
75JBR13-Z)
POINT
POINT
POINT
Switch setting of the communication unit
When using the MELSECNET/H communication unit,
the switch setting is not needed.
When using the MELSECNET/H communication unit,
the switch setting is not needed.
For details of each setting switch and LED, refer to the
following manual.
following manual.
GT15 MELSECNET/10 communication unit
User's Manual
User's Manual
(1) Network number setting switch
(2) Group number setting switch
*1
The GOT does not use the group number.
Specify "0".
Specify "0".
Item
Description
Range
Host
The host is displayed. (The host
is indicated with an asterisk (*))
is indicated with an asterisk (*))
―
N/W No.
Set the network No. of the
connected Ethernet module.
(Default: blank)
connected Ethernet module.
(Default: blank)
Network No. of
CNC
*1
PLC No.
Set the station No. of the
connected Ethernet module.
(Default: blank)
connected Ethernet module.
(Default: blank)
Station No. of CNC
Type
Set the type of the connected
Ethernet module.
(Default: QJ71E71)
Ethernet module.
(Default: QJ71E71)
AJ71QE71
IP Address
Set the IP address of the
connected Ethernet module.
(Default: blank)
connected Ethernet module.
(Default: blank)
IP address of CNC
Port No.
Set the port No. of the connected
Ethernet module.
(Default: 5001)
Ethernet module.
(Default: 5001)
5001
Communication
UDP (fixed)
UDP (fixed)
Network number setting
switch
Description
Set value
Set the network No. of the
MELSECNET/10
communication unit.
(Default: 001)
MELSECNET/10
communication unit.
(Default: 001)
1 to 239
Group number setting
switch
Description
Set value
Set the group No. of the
MELSECNET/10
communication unit.
(Default: 0)
MELSECNET/10
communication unit.
(Default: 0)
0: No group
setting
setting
(fixed)
*1
8
0
7
F
6
E
5
D
4
C
3
B
2
A
1
9
MODE
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
STATION
No.
X10
X1
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
NETWORK
No.
No.
X10
5
0
6
1
7
2
8
3
9
4
X100
X1
5
0
6
1
7
2
8
3
9
4
GROUP No.
RUN
PC
DUAL
SW.E
M/S.E
PRM.E
CRC
OVER
AB.IF
TIME
DATA
UNDER
LOOP
SD
RD
RD
POWER
D.LINK
T.PASS
GOT R/W
CRC
OVER
AB.IF
TIME
DATA
UNDER
LOOP
SD
RD
D.LINK
T.PASS
GOT R/W
CRC
OVER
AB.IF
TIME
DATA
UNDER
LOOP
SD
RD
E
R
R
O
R
R
R
O
R
E
R
R
O
R
R
R
O
R
F.LOOP
R.LOOP
GT15-75J71LP23-Z, GT15-75J71BR13-Z
(4)
(2)
(1)
(3)
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
NETWORK
No.
No.
X10
5
0
6
1
7
2
8
3
9
4
X100
X1
5
0
6
1
7
2
8
3
9
4
GROUP No.