18. CNC CONNECTION
18.6 Device Range that Can Be Set
18 - 23
17
ROBOT  CONT
ROLLER 
CONN
E
C
T
ION
18
CNC CONNECTION
19
GOT
 MUL
T
I-
DROP
 
C
O
NNECTION
20
MUL
TIPLE-G
T14
, GT
12, 
GT1
1, G
T10 
C
O
NNEC
TI
O
N FUNCTIO
N
21
MUL
T
I-CHANNEL
 
FUN
C
TIO
N
22
F
A
 TRANSP
A
R
E
N
FUNC
TION
18.6 Device Range that Can Be Set
For details of the device range that can be used on the GOT, refer to the following.
18.7 Precautions
18.7.1 Direct connection to CPU
Version of CNC
For MELDAS C6/C64, use NC system software version 
D0 or later.
18.7.2 MELSECNET/10 connection
Network configuration
Use the MELSECNET/10 mode of MELSECNET/H 
(PLC to PLC network) or MELSECNET/10 (PLC to PLC 
network) to configure a network including the GOT.
(1) The following networks including the GOT cannot be 
configured.
• MELSECNET/10 (Remote I/O network)
• MELSECNET/H (Remote I/O network)
(2) When configuring the network (MELSECNET/H 
(PLC to PLC network) including the GOT, refer to the 
following.
Monitoring range
Only CNC of the same networks No. can be monitored 
in GOT.
For details, refer to the following manual.
Starting GOT with CNC connection 
(MELSECNET/10 connection)
With the CNC connection (MESLSECNET/10 
connection), the data link starts approximately 10 
seconds after the GOT starts.
When a network error occurs in the system 
alarm
When a system alarm regarding a network error occurs 
with the CNC connection (MELSECNET/10 
connection), the system alarm is kept displaying on the 
GOT even though the error factor is removed.
To cancel the system alarm display, restart the GOT.
Version of CNC
For MELDAS C6/C64, use NC system software version 
E0 or later.
18.7.3 CC-Link (ID) connection
Using cyclic transmission
(1) I/O signal for master station
Do not turn on the reserved output signals in the output 
signals (remote output: RY) to the GOT from the master 
station.
When the reserved output signal is turned on, the CNC 
system may be malfunctioned.
For the assignment of I/O signals in the GOT, refer to 
the following manual.
MODEL GT15-J61BT13 CC-Link 
communication unit User's Manual
GT15 CC-Link communication unit User's 
Manual
(2) CC-Link Mode
CNC is not compatible with CC-Link Ver.2.
(3) When GOT malfunctions
The cyclic output status remains the same as before 
becoming faulty.
For transient transmission
(1) Access range that can be monitored
The GOT can access to the CNC mounting the master 
and local station of the CC-Link System.
It cannot access another network via the CC-Link 
module.
GOT startup in CNC connection (CC-Link 
connection (intelligent device station))
In the CNC connection (CC-Link connection (intelligent 
device station)), the data link is started approximately 
10 seconds after the GOT startup.
When a network error occurs in the system 
alarm
In the CNC connection (CC-Link connection (intelligent 
device station)), when a network error occurs in the 
system alarm, the system alarm message cannot be 
canceled even though the causes are removed.
To cancel the system alarm display, restart the GOT.
Version of CNC
For MELDAS C6/C64, use NC system software version 
D0 or later.