20.5 Precautions
GOT's communication timing
(1) GOT's communication timing
Adjust the communication timing so that, after applying 
the power to the system, the communication with the 
connected device (MITSUBISHI PLC) is performed in 
order starting from the first GOT (from the 1st GOT to 
the 2nd, and so on).
When the communication is failed, retries are 
performed. And if the predetermined time has elapsed, 
a communication error occurs.
• If the first GOT is turned on after a while the second 
GOT is turned on, because the communication start of 
the second GOT is delayed, a communication error 
may be detected at the second GOT.
• If the system power is turned on simultaneously and it 
takes time to start the communication of the second 
GOT, a communication error may be developed.
(2) Adjusting communication timing
(a) When powering up the system simultaneously
Using the utility or selecting [GOT Setup] - 
[Opening Screen Time] from GT Designer3, set the 
opening screen time adding a delay to each setting 
for the GOTs.
During the opening process, communication with 
the connected device does not start.
Example: Set value of [Opening Screen Time] 
(Inside (): set value)
First module (5s)   Second module (10s)
(b) When powering on devices individually
Turn on the connected device first, and then the 
first GOT, the second GOT, and so on.
Using the FA transparent function
When multiple GOTs are connected, the FA transparent 
function is not available even if the RS-232 interface or 
USB interface is used for the connection.
(When connecting a personal computer to the first 
GOT, the FA transparent function can be used.)
Monitoring stop condition for the GOT in the 
multiple-GT11 connection
In the system where multiple GOTs are connected, 
performing either of the following monitoring stop 
operations on the preceding stage (the first GOT) also 
stops monitoring of the GOT on the next stage (the 
second GOT).
When the GOT on the preceding stage resumes 
monitoring, the GOT on the next stage also resumes it.
• When project data or the OS is written/read by GT 
Designer3
*1
• When the GOT is set up
*1
*1
A timeout error occurs in GX Developer.
When PLC power disconnection occurs in 
the multiple-GOT connection
In the system where multiple GOTs are connected, 
when the communication between the PLC and the first 
GOT is stopped due to PLC power disconnection and a 
disconnection of the communication cable between the 
PLC and the first GOT, the GOT waits for timeout 
against the communication request from the peripheral 
devices (GX Developer, etc.), and recovery of 
monitoring between the PLC and the GOT is delayed.
user screen
user screen
The title screen
is displayed.
Power supply (24V DC)
Power feeding to GOT
First GOT's 
communication
Second GOT's 
communication
Retry
Communication of the
2nd GOT is enabled.
PC
PC
1st GOT
2nd GOT
RS-232
PC
1st GOT
USB
GT Designer3
1st GOT
2nd GOT
USB
The project data is being download.
Monitoring
stopped
Downloading
1st GOT
2nd GOT
Monitoring
Monitoring