2 - 8
2. DEVICE RANGE THAT CAN BE SET
2.1 MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700
2.1 MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700
The table below shows the device ranges in  [MELSEC-
QnU/DC, Q17nD/M/NC/DR, CRnD-700]
*10
 as the 
controller type.
*1
Do not set a file register by GT Designer3 when executing 
multiple programs with the file of the file register set at [Use 
the same file name as the program] by the PLC parameter of 
GX Developer. 
Otherwise, read/write at GOT will be erroneous.
*2
Available for file register of block No. switched with the RSET 
instruction.
*3
Available for file register of block No. of file name switched 
with the QDRSET instruction.
*4
GOT treats them in units of 32k (32768 points).
*5
Only the intelligent function module on the station connected 
to GOT can be specified.
Set within the address range of the buffer memory existing in 
the target intelligent function module.
*6
Do not use local devices set in the MELSEC-Q system.
Otherwise, normal monitoring is not performed.
*7
Even though Universal model QCPU processes 64-bit data, 
the GOT cannot monitor 64-bit data.
*8
This is not supported by GT10.
*9
This cannot be monitored when in GOT multi-drop 
connection.
*10
For GT14, GT11 and GT10, the controller type is as follows.
• GT14, GT11: MELSEC-QnU/DC, Q17nD/M/NC/DR
• GT10: MELSEC-QnU/DC
*11
For monitoring the internal relay (M) or data register (D) of a 
C Controller module, configure the settings related to the 
device functions in the device setting tab of the language 
controller setting utility.
*12
The device No. must be set in multiples of 16.
Device name
*7
Setting range
Device No. 
representation
Bi
t de
vi
ce
Input (X)
X0
to
X3FFF
Hexadecimal
Output (Y)
Y0
to
Y3FFF
Internal relay (M)
*4*6*11
M0
to
M61439
Decimal
Latch relay (L)
L0
to
L32767
Annunciator (F)
F0
to
F32767
Link relay (B)
*4
B0
to
B9FFFF
Hexadecimal
Timer
*6
Contact (TT)
TT0
to
TT32767
Decimal
Coil (TC)
TC0
to
TC32767
Counter
*6
Contact (CT)
CT0
to
CT32767
Coil (CC)
CC0
to
CC32767
Special relay (SM)
SM0
to
SM2255
Retentive 
timer
*6
Contact (SS)
SS0
to
SS32767
Coil (SC)
SC0
to
SC32767
Step relay (S)
S0
to
S32767
Link special relay (SB)
SB0
to
SB7FFF
Hexadecimal
Word device bit
Specified bit of the 
following word devices
(Except Timer, Counter, 
Retentive timer, Index 
register and Buffer 
memory)
W
o
rd
 device
Data register (D)
*4*6*11
D0
to
D4910079
Decimal
Special data register (SD)
SD0
to
SD2255
Link register (W)
*4
W0
to
W4AEBFF
Hexadecimal
Timer (current value) (TN)
*6
TN0
to
TN32767
Decimal
Counter (current value) 
(CN)
*6
CN0
to
CN32767
Retentive timer 
(current value) (SN)
*6
SN0
to
SN32767
Link special register (SW)
SW0 to
SW7FFF
Hexadecimal
File register (R)
*1*2
R0
to
R32767
Decimal
Extension 
file register 
(ER)
*1
Block
0
to
255
Device
ER0
to
ER32767
Extension file register 
(ZR)
*1*3*4
ZR0
to
ZR4849663
Index register (Z)
Z0
to
Z19
Buffer memory 
(Intelligent function module) 
(BM)
*5
BM0
to
BM32767
Buffer memory
(Intelligent function module)
(G)
*4*5
G0
to
G65535
Ww
*8*9
Ww0 to
Ww1FFF
Hexadecimal
Wr
*8*9
Wr0
to
Wr1FFF
Multiple CPU high speed 
transmission memory (U3E0)
U3E010000 to U3E024335
Multiple CPU high speed 
transmission memory (U3E1)
U3E110000 to U3E124335
Multiple CPU high speed 
transmission memory (U3E2)
U3E210000 to U3E224335
Multiple CPU high speed 
transmission memory (U3E3)
U3E310000 to U3E324335
Motion device (#)
#0
to
#12287
Decimal
Bit device word
*8*12
Converting the above bit 
devices into words
(Except Timer, Counter 
and Retentive timer)
Device name
*7
Setting range
Device No. 