Cirkuit Planet MH-2001 用户手册

下载
页码 297
MH-2001 Multi-Homing Security Gateway User’s Manual 
The A Company‘s default gateway is the MH-2001 LAN IP 192.168.10.1. Make the following 
settings: 
 
STEP 1 . Enter A Company‘s MH-2001 default IP Address 192.168.10.1. In Policy Object 
Æ VPN Æ IP Sec 
Autokey 
Æ New Entry.
 
 
 
IPSec Autokey 
 
 
STEP 2 . In IPSec Autokey, enter VPN_A in the VPN Name. In WAN interface, select WAN 1, which the A 
Company use it to build the VPN. 
 
 
The IPSec VPN name and WAN interface setting 
 
STEP 3 . In To Destination, select Remote Gateway – Fixed IP or Domain Name. Enter the Remote IP 
address to link to B Company.
 
 
 
The IPSec To Destination setting   
 
STEP 4 . In Authentication Method, select Preshare, enter the Preshared Key. (the maximum Preshared 
Key is 100 bytes). 
 
 
The IPSec Authentication Method setting 
 
 
 
 
- 183 -