Maretron DCM100 用户手册

下载
页码 24
 
 
 
 
 
 
 
Revision 1.0 
 
Page 15 
®
®
Environmental 
Parameter 
Value 
IEC 60954 Classification 
Exposed 
Degree of Protection 
IP64 
Operating Temperature 
-25°C to 55°C 
Storage Temperature 
-40°C to 70°C 
Relative Humidity 
93%RH @40° per IEC60945-8.2 
Vibration 
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 
Rain and Spray 
12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8? 
Solar Radiation 
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 
Corrosion (Salt Mist) 
4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 
Electromagnetic Emission 
Conducted and Radiated Emission per IEC 60945-9 
Electromagnetic Immunity 
Conducted, Radiated, Supply, and ESD per IEC 60945-10 
Safety Precautions 
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12 
 
 
9  Technical Support 
If you require technical support for Maretron products, you can reach us in any of the following 
ways: 
 
 Telephone: 
1-866-550-9100 
 Fax: 
1-602-861-1777 
 
World Wide Web: 
 Mail: 
Maretron, 
LLC 
 
  Attn: Technical Support 
 
  9014 N. 23
rd
 Ave Suite 10 
 
  Phoenix, AZ 85021 USA