Maretron FPM100 用户手册

下载
页码 23
 
 
 
 
 
Revision 1.3 
 
Page 15 
®
®
Figure 9 – Troubleshooting Guide 
 
If these steps do not solve your problem, please contact Maretron Technical Support (refer to 
Section 7 for contact information). 
 
6  Technical Specifications 
Specifications (Tank Level Mode) 
Parameter 
Value 
Comment 
Accuracy +/-1% 
FS 
Exclusive of Pressure Transducer 
Resolution 
+/-0.33% FS  Over Full Pressure Transducer Range 
Number of Tank Types 
16 
Fuel, Fresh Water, Waste water, Live well, Oil, etc. 
Number of Tanks per Tank Type 
16 
16 Tanks per Tank Type Numbered 0-15 
Support for Irregularly Shaped 
Tanks 
Yes 
Can be Calibrated for any Shape Tank 
Programmable Tank Capacity 
Yes 
Allows Displays to Calculate Amount Remaining 
Specifications (Pressure/Vacuum Mode) 
Parameter 
Value 
Comment 
Accuracy +/-1% 
FS 
Exclusive of Pressure Transducer 
Resolution 
+/-0.33% FS  Over Full Pressure Transducer Range 
Number of Pressure Source Types 
21 
Water Pressure, Atmospheric Pressure, Compressed Air 
Pressure, Hydraulic Pressure, Steam Pressure, 16 User 
Defined Sources 
 
Certifications 
Parameter 
Comment 
NMEA 2000 
Level A 
Maritime Navigation and Radiocommunication Equipment & Systems 
IEC 61162-3 
Maritime Navigation and Radiocommunication Equipment & Systems 
Tested to IEC 60945 
FCC and CE Mark 
Electromagnetic Compatibility 
 
NMEA 2000
®
 Parameter Group Numbers (PGNs) - See Appendix A for Details 
Description 
PGN # 
PGN Name 
Default Rate 
Periodic Data PGNs 
127505  Fluid Level 
0.4 Times/Second 
130314  Actual Pressure 
0.5 Times/Second 
Response to Requested PGNs 
126464  PGN List (Transmit and Receive) 
N/A 
126996 Product 
Information 
N/A 
126998 Configuration 
Information 
N/A 
Protocol PGNs 
059392  ISO Acknowledge 
N/A 
059904 ISO 
Request 
N/A 
060928 ISO 
Address 
Claim 
N/A 
065240 ISO 
Address 
Command 
N/A 
126208 NMEA 
N/A 
Maretron Proprietary PGNs 
128720  Configuration 
N/A