Lake Shore Model 620/622/623/647 Magnet Power Supply User’s Manual 
 
 
 
Mainframe Control Bus Operation
 
B-6
Table B-2 Additional MPS Mainframe Control Bus Remote Commands 
 
Input 
Command 
Query Function 
– ADR 
Mainframe address. Multidrop address 0-32 available. Commands 
sent must have the address as the first character. Query response 
will be “00” thru “32.” 
LOC 
LOCK 
UNLOCK 
REM 
CMD 
Mainframe Programming Status. Query response will be the same 
as what is programmed. There is no real change in Mainframe 
status. MPS equivalent commands are:
 
LOC UNLOCK 
 MODE0  MODE0 
LOCK REM 
MODE2 
MODE1 
– 
 
 
ERRC 
Mainframe Operational Status. Query response is status byte 
register contents, comma, standard event status register contents 
(equivalent to *STB? and *ESR? queries). Form of the response is 
XXX,XXX where XXX ranges from 000 to 255. *SRE and *ESE are 
forced to 255 to get a status response. 
– 
S1 
Mainframe Error Status. Query response is equivalent to ERR?. 
WA 
RA 
Output Current Setting. MPS equivalent commands are:
 
WA ISET 
ISET? 
RA 
PO 
OP 
Output Current Polarity Setting and Status. 
– 
AD1, AD8  Output Current Measurement. MPS equivalent command: IOUT? 
– 
AD2 
Output Voltage Measurement. MPS equivalent command: VOUT? 
– 
AD3 – AD7  Internal Control Voltages. Query response forced to 000 until 
required responses are defined. 
BAUD 
– 
Communications Baud Rate (Not Supported). Fixed at 9600. 
– 
Turn Mainframe Power ON (Not Supported). 
– 
Turn Mainframe Power OFF (Not Supported). 
RS 
– 
Reset Mainframe Faults. (Only action taken is I Step Reset.)