Chapter 3 — Configuring the Computer
92
751G Color Mobile Computer User’s Manual
Helper Functions
ConfigureProfile()
If using the Intermec 802.11b/g Profile Management system, you can 
program the API to configure the radio to a specific profile by passing the 
profile name.
EnableSuppLogging()
Call this function to set the desired supplicant logging mode.
Syntax
UINT ConfigureProfile( TCHAR * );
Parameters
Pointer to a character array that contains the profile name. This should be 
null-terminated.
Return Values ERROR_SUCCESS when successful, ERR_QUERY_FAILED when the 
query failed, or ERR_CONNECT_FAILED if a connection with the 
radio failed.
Remarks
Call this function with a pointer to a null-terminated TCHAR array that 
contains the name of the profile you wish to configure. This function 
reads profile data from the profile manager, sets that profile as the default 
active profile, and configures the radio appropriately. If needed, the 
supplicant and any other related services are automatically started and 
stopped.
Definitions
#ifdef DYNAMIC_LOADING
typedef UINT (*PFN_ConfigureProfile)(TCHAR *);
#else
UINT ConfigureProfile(TCHAR *);
#endif
Syntax
UINT EnableSuppLogging( ULONG );
Parameters
NDIS_SUPP_LOGGING_ON
Supplicant Logging Enabled
NDIS_SUPP_LOGGING_OFF
Supplicant Logging Disabled
Return Values ERROR_SUCCESS when successful.
Remarks
None.
Definitions
#ifdef DYNAMIC_LOADING
typedef UINT (*PFN_EnableSuppLogging)(ULONG);
#else
UINT EnableSuppLogging(ULONG);
#endif