EonStor A16E-G2130-4 Installation and Hardware Reference Manual  
D.6.2 UPS Messages 
The following messages may appear on the LCD screen: 
Message 1: “UPS connection is absent” 
This message appears when COM2 has not been connected to the UPS. 
Message 2: “UPS connection detected” 
This message appears when the COM2 ports on the subsystem have been 
connected to the UPS. 
Message 3: “Warning: UPS AC Power-Loss detected” 
This message appears when the UPS battery power level remains above 
50% but its connection to the AC power supply has been disrupted in some 
way. The write policy changes from write back to write through. 
Message 4: “Warning: UPS Battery Low 50%. Please shut down to protect 
data loss” 
This message appears when the UPS battery power level has dipped below 
50% of its capacity and the UPS has either been disconnected from the AC 
power supply or the AC power supply has been disrupted. The write policy 
will be changed from the default write back to write through. If this message 
appears, the subsystem should be properly shut down to avoid data loss. 
Message 5: “Warning: UPS Battery Low 50%” 
This message appears when the UPS battery power level has dipped below 
50% of its capacity. The default write policy will be changed from the 
default write back to write through. 
Message 6: “UPS Battery restored to safe level” 
This message appears when the UPS battery power level has been restored 
to above 50% of its capacity. The write policy will be changed from write 
through to write back. 
Message 7: “UPS AC Power Restored” 
This message appears when the AC power supply to the UPS has been 
reconnected. If the UPS battery power level is below 50%, the write policy 
will remain as write through. If the battery power level is above 50%, the 
write policy will change from write through to write back. 
 
D-4  
UPS Status Monitoring