INSTALLATION AND CONNECTIONS
■ Fixing the EX-2780 scanner unit
q Put the scanner unit*
1
on the stay, then fix the an-
tenna rotor with installation bolts of 8 mm (5/16 in)
in diameter, with flat and dish washers and a seal-
ing washer. Be sure to keep the direction of the dish
washer correct as shown in the diagram*
2
. (Fig. 4)
w Apply lubricant specified below or an equivalent one
to the motor bearing*
3
, if required. 
• Manufacture: ESSO
Type:
BEACON 325
e Connect the grounding wire to the ground plate with
the supplied terminal if required. (Fig. 5)
NOTE: When using the optional system cable.
Peel the outer sheath of the system cable when using
the optional system cable OPC-1078.
• BE CAREFUL ! DO NOT cut the inner shield wire
when peeling the outer sheath.
(Unit: mm)
Peel the sheath
To the display
To the scanner
18
±2
410
±5
*
2
*
1
Scanner   unit
Stay
Sealing
washer
Keep in this
direction
Installation
bolt
*
3
Lubricant spot
Fig. 4
Fig. 5