Honeywell Network Hardware NETAXS-123 用户手册

下载
页码 76
Installing the NetAXS-123 Panels
Hardware Specifications
NetAXS-123 Access Control Unit  Installation GuideDocument 800-05779, Revision A
61
Example
:
If the total current consumption of your external devices exceeds the 450mA maximum current 
maximum, then use one of the following system configurations: 
•   Power the panel with an external 12VDC power supply.  
•   Power some or all of the external devices with an external power supply to lower the 
total external current powered by the NetAXS-123 panel below 450mA.
• The maximum power available in the 802.3af standard is 15.4W. This limit is generally at 
48VDC, and it is measured at the output of the power injector or PoE switch.  Line losses cause 
a decrease in the power available at the panel when you use longer Ethernet cable lengths.  You 
can minimize these line losses by using either of the following methods:
•   Connecting the NetAXS-123 panel to the power injector or PoE switch with the shortest 
possible Ethernet cable length.
•   Using a high-power 802.3at power injector or PoE switch with a voltage of 56VDC. This 
reduces line losses and thus increases available power at the NetAXS-123 panel. 
Note: 
The NetAXS-123 panel will not benefit from the increased power capabilities of a 
high-power 802.3at power injector.  Its use only reduces line losses over the Ethernet 
cable.
5.5  Mechanical
• Standard Enclosure dimensions: Height = 14 inches (355.6 mm), Width = 12 inches (304.8 
mm), and Depth = 5 inches (127 mm).
• Compact Enclosure dimensions: Height = 7.5 inches (190.5 mm), Width = 7.5 inches (190.5 
mm), and Depth = 2.25 inches (57.15 mm).
Device Element
Current
Door strike or magnetic 
lock current
 250 mA
Reader A maximum 
current
 50 mA 
Reader B maximum 
current
 50 mA
Buzzer or sounder current
 20 mA
Door position switch
 20 mA
Request to exit switch
 30 mA
Total current for this 
example
420 mA