UTOLOADER
If the autoloader or tape drive has encountered an error and is not operating 
as expected after you have tried the recommended corrective actions, you may 
need to perform a reset. From the operator panel, you can reset the autoloader 
without resetting the tape drive. You can reset both the autoloader and the 
tape drive by powering the autoloader off and back on.
Note:
You may also be able to perform resets from your autoloader software. 
Refer to your software documentation for instructions.
Resetting the autoloader from the operator panel or powering the autoloader 
off and back on causes it to perform its power-on self-test and a cartridge 
inventory. Powering the autoloader off and back on to reset the tape drive 
causes the tape drive to perform its power-on self-test and to rewind a loaded 
tape to the beginning.
To reset the autoloader from the operator panel: 
1.
1.
1.
1.
At the Home screen, press 
, or 
 to access the main menus.
If necessary, enter the operator panel password (see 
).
2.
2.
2.
2.
Press 
 or 
 until the Diagnostic menu appears:
! ! 
Important
If you need to power the autoloader off, first unload the cartridge 
from the tape drive, if possible. If you power the autoloader off 
and back on while a cartridge is in the tape drive, the drive may 
have to perform a lengthy format recovery process.
If a cartridge is loaded in the tape drive when the autoloader is 
powered off and back on, the tape drive rewinds the tape but does 
not eject the cartridge. Make sure that it is safe to overwrite the 
tape before performing a backup so that you don’t lose previously 
recorded data. If necessary, unload the cartridge as described on 
.
! ! 
Important
Before resetting, make sure that the autoloader or tape drive is not 
communicating across the bus. The reset may disrupt 
communications on the bus.
P e r f o r m
a