Setup & Operation    3. Environments and Installation 
 
28 
G10 / G20 Rev.2 
 
3.2  Base Table 
A base table for anchoring the Manipulator is not supplied.    Please make or obtain the 
base table for your Manipulator.    The shape and size of the base table differs depending 
on the use of the robot system.  For your reference, we list some Manipulator table 
requirements here. 
 
The base table must not only be able to bear the weight of the Manipulator but also be able 
to withstand the dynamic movement of the Manipulator when the Manipulator operates at 
maximum acceleration.  Ensure that there is enough strength on the base table by 
attaching reinforcing materials such as crossbeams. 
The torque and reaction force produced by the movement of the Manipulator are as 
follows: 
 
G10 G20 
Max. Reaction torque on the horizontal plate 
1000 Nm 1000 
Nm 
Max. Horizontal reaction force 
4500 N 7500 
Max. Vertical reaction force 
2000 N 2000 
The threaded holes required for mounting the Manipulator base are M12.    Use mounting 
bolts with specifications conforming to ISO898-1 property class: 10.9 or 12.9. 
For dimensions, refer to Setup & Operation: 3.3 Mounting Dimensions
The plate for the Manipulator mounting face should be 20 mm thick or more and made of 
steel to reduce vibration.    The surface roughness of the steel plate should be 25 µm or 
less. 
The table must be secured on the floor or wall to prevent it from moving. 
The Manipulator must be installed horizontally. 
When using a leveler to adjust the height of the base table, use a screw with M16 diameter 
or more. 
If you are passing cables through the holes on the base table, see the figures below.   
[unit : mm] 
 
Power Cable 
Connector 
95 
Signal Cable 
Connector 
47
26
53
18 
M/C Cables 
 
Do not remove the M/C cables from the Manipulator. 
)
NOTE
 
For environmental conditions regarding space when placing the Controller on the base 
table, refer to the Controller manual
 
 
WARNING 
■  To ensure safety, a safeguard must be installed for the robot system. 