2-26
1. Operation of V7 Main Menu
Connection with CU-03 on V7
1. Select either [10BASE-T] or [AUI] for the connecting method.
2. Set the IP address. (If necessary, set the default gateway and subnet mask.)
3. Press the [Setting Finished] switch. The settings are determined.
4. The Main Menu screen is displayed again.
2. Set the IP address. (If necessary, set the default gateway and subnet mask.)
3. Press the [Setting Finished] switch. The settings are determined.
4. The Main Menu screen is displayed again.
• Rotary Switch and Network Table
Register IP addresses and other information for the V series, PLCs or computers that
should be included for Ethernet communications on the V-SFT editor. ([System Setting]
→ [Network Table Setting] → [Ethernet] → [Edit Network Table]) Set the network table
number with the rotary switch on the communication interface unit CU-03.
should be included for Ethernet communications on the V-SFT editor. ([System Setting]
→ [Network Table Setting] → [Ethernet] → [Edit Network Table]) Set the network table
number with the rotary switch on the communication interface unit CU-03.
0
0
0
0
0
0
0
10000
0
0
0
10BASE-T
0
0
<-
->
Return
Ethernet
It is not used when the gate way or the sub-mask is zero.
IP Address:
Gate Way:
Sub-mask:
Port No.
Connect
Setting
Finished
Cursor switches
[Increment/Decrement] switch for the value
in the cursor position
in the cursor position
Determines the setting such as IP address,
and moves back to the Main Menu screen.
and moves back to the Main Menu screen.
Used for checking the 10BASE-T interface.
Normal: Connect
Error:
Error:
Disconnect
Moves back to the Main Menu screen.
IP address, gateway and sub-mask settings
Selects [10BASE-T] or [AUI].
Port number to be set
with the rotary switch on
the communication
interface unit CU-03
with the rotary switch on
the communication
interface unit CU-03