Installing the Module into the 5C105 Chassis
Installation
3-3
3.2
INSTALLING THE MODULE INTO THE 5C105 CHASSIS
To install a module, refer to 
 and proceed as follows:
1. Remove the blank panel covering the slot in which the module will be installed. All other slots 
must remain covered to ensure proper airflow and cooling. (Save the blank plate in the event 
you need to remove the module.)
2. Carefully remove the module from the shipping box. (Save the box and packing materials in the 
event the module must be reshipped.)
3. Locate the antistatic wrist strap shipped with the module. Attach the antistatic wrist strap to 
your wrist and plug the cable from the antistatic wrist strap into the ESD grounding receptacle 
at the upper right corner of the chassis.
4. Remove the module from the plastic bag. (Save the bag in the event the module must be 
reshipped.) Observe all precautions to prevent damage from Electrostatic Discharge (ESD).
5. Examine the module for damage. If any damage exists, DO NOT install the module. 
Immediately contact Enterasys Networks. Refer to 
, in 
CAUTION: Failure to observe static safety precautions could cause damage to the 
module. Follow static safety handling rules and wear the antistatic wrist strap provided 
with the 5C105 Chassis.
Do not cut the non-conductive bag to remove the module. Sharp objects contacting the 
board or components can cause damage.
CAUTION: To prevent damaging the backplane connectors in the following step, take 
care that the module slides in straight and properly engages the backplane connectors.
Ensure that the top plastic locking tab lines up with the desired slot number located on 
the front panel of the chassis. Refer to