 Chapter 2: Installation        23
To install the HMX 1070 or HMX 2050 user station and associated transmitter on a 
network:
1. Connect the transmitter to the remote workstation. Connect one end of the UTP cable to the 
transmitter’s RJ-45 connector. Connect the other end of the UTP cable to the Ethernet network.
2. Connect the user station to the peripherals. Use a length of UTP cable to connect the user 
station to the Ethernet network via the RJ-45 connector on the rear of the user station. 
3. Turn on the user station. A connection will be automatically established with the remote 
workstation.
4. Use the serial menu to reconfigure the network settings for the transmitter.
NOTE: If the user station and associated transmitter are to be located on different subnets, configure their 
network settings before you connect to the network.
NOTE: If there are already transmitters and user stations operating on the subnet, configure network settings of 
the new transmitter and user station pair before connecting them to the network.
5. Use the serial menu to reconfigure the network settings for the user station.
6. Repeat this procedure for each transmitter and user station pair you wish to install on the 
network.
To install the HMX system on a network in Desktop Mode:
1. Ensure that each transmitter and user station has a unique IP address.
2. Using the HMX Manager, locate and add the units to the HMX Manager database. For 
information on how to do this, refer to the HMX Manager Installer/User Guide.
Table 2.10: HMX System Default Network Settings (HMX 2050 User Station)
Component
IP Address
Type
Default 
Gateway
Subnet Mask
HMX 2050 User 
Station
192.168.13.1
Static
0.0.0.0
255.255.255.0
HMIQDHDD 
Transmitter
192.168.13.2
Static
0.0.0.0
255.255.255.0