NICD/NIMH FUNCTIONS AND PARAMETERS 
Page 3
Page 1
Page 2
05]NiMH  6S  3000mAh
 CHG.  : 3.0A   8mV/C
 DCHG. : 3.0A  0.8V/C
 CYCLE :  C
D  1x 10m
CUT.TEMPER. :   55°C
 MAX.CAPACITY:   150%
 PEAK DELAY  :   3min
 TRI CURRENT :  100mA
SAFETY TIMER: 120min
Cut-off Temperature
Cut-off when x% of 
capacity is reached.
Do not detect peaks 
for x mins.
Trickle Charge Rate
Cut-off if maximum 
time is reached
Charge
Cycle
Discharge
 
‘CHG.’  –  CHARGE 
This line shows the charge current and the delta-peak cut-off voltage. These values 
can be edited by pressing the ‘Enter’ button to highlight the parameter, then the ‘Inc’ 
and ‘Dec’ buttons to edit the value.  
When charging NiCd and NiMH batteries, most chargers detect when the pack is fully 
charged by using a method called delta-peak. This monitors the voltage of the pack 
which increases as the pack becomes charged. When the pack is fully charged the 
pack starts to get warm and the voltage then starts to drop. The delta-peak cut-off 
voltage is the voltage drop (per cell) that is detected before the charger will stop the 
charge. The default delta-peak voltage setting for NiMH packs is 5mV/cell and for 
NiCd is 8mV/cell. 
To start the charge function, press the ‘Enter’ button for 2 seconds with this line 
selected. The screen will then move to the charge type screen (see page 12). 
n.b.   The selected charge currents will not be used if ‘Automatic’ charge type is 
selected.  
‘DCHG.’  -  DISCHARGE  
The discharge line shows the discharge current and the discharge cut-off voltage (per 
cell). The default cut-off voltage for NiCd/NiMH cells is 0.8V/cell. 
 Pressing the ‘Enter’ button for 2 seconds with this line selected will move to the 
discharge type selection screen.  
n.b.   The selected discharge current will not be used if ‘Automatic’ discharge type is 
selected.