is assigned to this uplink set (because, for example, 1_NET is to be deleted),
then you can restore the LAN connection to the IBP by adding the port to the
standard uplink set. Enter the following commands:
(Vty-0) #configure
(Vty-0) (Config)#interface 0/11
(Vty-0) (Interface 0/11)#uplink-set default
(Vty-0) (Interface 0/11)# exit
(Vty-0) (Config)#exit
(Vty-0) #
In these cases, however, the configuration used from VIOM no longer
matches the actual configuration. In this case, you should use the VIOM user
interface for the affected IBP module to restore the configuration.
l
To do this, go to the Setup tab and click the affected IBP module in the
rear view of the blade server chassis.
The details for the IBP module and the Restore IBP button are then dis-
played at the bottom on the right.
l
Click the Restore IBP button. The IBP module is then programmed
according to the configuration saved in VIOM.
4.2
Configurations on the managed BX400 Blade
Server
In section
you can find out what combinations of I/O connection blades are
supported by VIOM.
To manage a blade server with VIOM, you must carry out the following pre-
paratory steps:
l
Configure the management blade or management blades, see section
l
Configure the I/O connection blades, see section
ServerView Virtual-IO Manager
109
4.2 Configurations on the managed BX400 Blade Server