21. PRE-SET STARTER CRANKING TIME:  (Requires Option #16 in “Pre-Set” Setting)
 
This option controls the starter cranking time when in “Timed Crank” Mode.  Choices are 0.5, 0.75, 1.0, or 1.5 sec. 
 
22. DIESEL GLOW PLUG DELAY 
This option controls the system’s Diesel vehicle interface. Using this option you can control whether the unit 
monitors the vehicle’s glow plug circuit using the Pink input wire (Default), or you may select a specific delay time  
Before cranking.  This option is helpful if you are unable to locate a glow plug signal.  Just select a delay time and 
do not connect the Pink Glow Plug wire.  Selections: 10, 20, 30 seconds, or Monitor Pink Wire (Default). 
 
23. REMOTE START ENGINE RUN TIME: 
Set engine run time for 12, 24, 36 or 48 minutes as desired. 
 
24. ULTRA-SMART TACHLESS VOLTAGE ADJUSTMENT:
 
This  option  controls  the  voltage  reference  point  when  using  smart  Tachless  mode.    Pressing  the  Lock  or  Unlock 
buttons on the remote raises or lowers the reference level in 1% increments from 79%-%100.  Button #3 resets the 
unit to the factory default reference point of 93%.  The default 93% setting works for most vehicles.  See page 15 for 
additional Ultra-Smart Tachless mode information. 
 
25. FACTORY HORN CHIRPS / PULSES: 
This option controls the system’s horn honk output.  There are 3 selections: 
4 Button 1 (Lock): Pulse horn when alarm is triggered.   
4 Button 2 (Unlock): Pulse horn when alarm is triggered and Honk when Alarm is Armed and Disarmed. 
4 Button  3  (Trunk  Pop):  Pulse  horn  when  alarm  is  Triggered,  Honk  when  Alarm  is  Armed  and  Disarmed  and 
Pulse when Shock pre-warning is set off. (default) 
4 Button 4 (Start): Short Arm/Disarm Chips. Reduces the pulse from 0.04 to 0.02 seconds. 
26. Aux #3: (Violet/White wire) 
This option controls the function of the Violet/White wire for a negative output for a Momentary, Pulse, Timed or 
Latched output, depending on option used. Option #27 controls the length of time output. 
 
 
27. Aux #3 Time control: (1 sec. to 255 sec.) Default = 12 seconds 
This  option  determines  the  length  of  time  that  is  outputted  from  Aux  #3  (Violet/White  wire).    Pressing  the  Lock  or 
Unlock buttons on the remote raises or lowers the time by one second. 
 
28. Aux #4: (Green/White wire) 
This option controls the function of the Green/White wire for a negative output for a Momentary, Pulse, Timed or 
Latched output, depending on option used. Option #29 controls the length of time output.