Cognitive Solutions All in One Printer B780 用户手册

下载
页码 192
Chapter 6:  DH Emulation  149
A776-PG00001 C 12/09 
 
A776 (B780) Programming Guide
Document Clamp Close
Closes the platen when the form has been detected and the time for the clamp delay is up. This command enables the 
Slip/Validation paper feed and disables the Receipt/Journal paper feed.
  Hexadecimal  Decimal  ASCII 
  1B 1C 
27 28 
ESC FS 
Form Eject
Ejects the form from the validation station after it has been printed.
  Hexadecimal  Decimal  ASCII 
  1B 41 
27 65 
ESC A 
Download
This command is not supported and is ignored if received.
  Hexadecimal  Decimal  ASCII 
  1B 42 75 
27 66 117  ESC B u 
Form In
This command is not supported and is ignored if received.
  Hexadecimal  Decimal  ASCII 
  1B 46 
27 70 
ESC F 
Select
This command is not supported and is ignored if received.
  Hexadecimal  Decimal  ASCII 
  1B 47 
27 71 
ESC G 
Either Form-In Sensor
This command is not supported and is ignored if received.
  Hexadecimal  Decimal  ASCII 
  1B 49 
27 73 
ESC I 
Both Form-In Sensors
This command is not supported and is ignored if received.
  Hexadecimal  Decimal  ASCII 
  1B 4A 
27 74 
ESC J 
Busy Until Buffer Empty
Changes the state of the RTS (Request to Send) line until the buffer is empty. This command is processed immediately.
  Hexadecimal  Decimal  ASCII 
  1B 4B 
27 75 
ESC K 
Clamp Delay
Sets the time that the printer waits from when it detects an inserted form to when it clamps the platen closed. This 
allows time for the form to be lined up correctly and held still.
  Hexadecimal  Decimal  ASCII 
Value of n 
  1B 4C n 
27 76 n 
ESC L n  See table 
  Value of n 
 
  Hexadecimal  Decimal  ASCII 
Time of Clamp Delay 
  00 
0  
NUL 
No delay 
  01 
1  
SOH 
0.250 seconds 
  02 
2  
STX 
0.500 seconds (default) 
  03 
3  
ETX 
1.00 seconds