Installation / 
Assemb
ly
2009 Fireplaces and Firepits
LTR20091006, Rev. B
www.calspas.com
Natural Gas
The appliance and its individual shut off valve must be disconnected 
from the gas supply piping system during any pressure testing of the 
system at test pressures in excess of ½ psig (3.5kPa).
This appliance must be isolated from the gas supply piping system by 
closing its individual manual shut off valve during any pressure testing 
of the gas supply piping system at test pressures equal to or less than 
1/2 psig (3.5kPa).
Requirements
Always  check  the  rating  plate  to  make  sure  the  gas 
supply  you  are  hooking  up  to  is  the  gas  type  the  
firepit or fireplace is manufactured for.
The  installation  of  this  appliance  must  conform  with  lo-
cal  codes  or,  in  the  absence  of  local  codes,  to  the  
national fuel gas code, ANSI Z223.1a-1998. Installation in Canada must 
be in accordance with the standard CAN/CGA-B149.2, Propane Instal-
lation Code. Natural gas connection must be performed by a licensed 
contractor or local gas company representative.
Ensure that the service supplying the firepit or fireplace is fitted with a 
conveniently positioned shut off valve with easy access.
Installation
Connect the incoming gas supply line to the on/off gas valve of the 
appliance.  Make  certain  ALL  gas  connections  are  tight,  turn  the  on/
off valve at the unit to the ‘on’ position and use soap and water to 
test for leaks. Gas will be released at the burner for this duration. DO 
NOT  USE  AN  OPEN  FLAME  AND  REMOVE  BATTERY  FROM  IGNITER 
BEFORE PERFORMING THIS TEST. An authorized gas appliance 
installer must provide this installation service. Note that the 
correct natural gas orifice must also be installed prior to fuel line hook 
up to maintain proper flame height and clean burn of fuel.