Cal Flame FIREPIT LTR20091006 用户手册

下载
页码 32
Installation / 
Assemb
ly
17
2009 Fireplaces and Firepits
LTR20091006, Rev. B
www.calspas.com
High Elevation Installation
Your fireplace or fire pit is approved for elevations up to 4500 feet in 
the US and Canada.
When installing this appliance at an elevation above 4500 feet in the 
US, it may be necessary to decrease the input rating by changing the 
existing burner orifice to a smaller size. Reduce the input by 4% for 
each 1,000 feet above sea level, unless the heating value of the gas 
has been reduced, in which case this general rule will not apply. To 
identify the proper orifice size, check with your local gas utility.
When installing this unit at an elevation above 4,500 feet in Canada 
check with your local authorities. Consult the local gas utility for assis-
tance in determining the proper orifice for your location.
Natural Gas Conversion
For Both Fireplaces or Fire Pits
CAUTION: This service is to be completed only by an authorized gas 
appliance  installer.  Do  not  attempt  this  conversion  on  your  own  as 
there is risk of serious injury or death.
To The Authorized Gas Appliance Installer:
All  Cal  Flame  fireplaces  and  firepits  are  shipped  from  the  factory 
equipped  to  burn  on  liquid  propane  fuel.  Enclosed  with  this  kit  is  a 
natural gas conversion kit for converting this unit to natural gas. To 
perform this conversion, follow the directions below and to the local 
regulation standards in your area. 
Make sure unit is not in operation and is cool enough to perform 
1. 
this service. Shut off and disconnect propane fuel source at the 
regulator end.
Carefully remove the storage cover, lava rocks and fire logs. Turn 
2. 
unit over to access hose connections underneath.  
While holding the propane orifice in place with a wrench, unscrew 
3. 
brass  fitting  on  fuel  inlet  hose.  Unscrew  propane  orifice  and  re-
move. 
Using the new brass natural gas orifice re-install the parts in the 
4. 
same sequence. Turn the protective screen / air intake sleeve to al-