Leak Testing Procedure
Perform a leak test at least once a year whether the gas supply cylinder 
has been disconnected or not. In addition, whenever the gas cylinder 
is connected to the regulator or whenever any part of the gas system 
is disconnected or replaced, perform a leak test.  
As  a  safety  precaution,  remember  to  always  leak  test  your  fireplace 
or firepit outdoors in a well-ventilated area.  Never smoke or permit 
sources of ignition in the area while doing a leak test.  Do not use a 
flame, such as a lighted match to test for leaks. Use a solution of soapy 
water.
Prepare a leak testing solution of soapy water by mixing in a spray 
1. 
bottle one part liquid soap to one part water.
Make sure all the control knobs are in the OFF position.
2. 
Turn on the gas.
3. 
On natural gas systems, turn the main feed valve to the burn-
er.
On LP systems, turn the cylinder valve knob counter clockwise 
one turn to open.
Apply the leak-testing solution by spraying it on joints of the gas 
4. 
delivery  system.  Blowing  bubbles  in  the  soap  solution  indicates 
that a leak is present.
Stop a leak by tightening the loose joint or by replacing the faulty 
5. 
part with a replacement part recommended by the manufacturer. 
Do not attempt to repair the cylinder valve if it is damaged. The 
cylinder must be replaced.
Turn the control knob back to the full OFF position.
6. 
If you are unable to stop a leak:
Turn the control knob back to the full OFF position.
1. 
Shut off the gas supply to the fireplace or firepit and release pres-
2. 
sure  in  the  hose  and  manifold  by  turning  the  control  valve  one 
quarter turn counter-clockwise.
 On LP systems, remove the cylinder from the fireplace or firepit.
3. 
Call an authorized gas appliance service technician or an LP gas 
4. 
dealer.
Do not use the appliance until the leak is corrected.