Adjusting Sensitivity Levels 
 
The  Leak  Detector  will  default  to  the  NORM  sensitivity  level 
automatically once the unit comes out of the warm up cycle and 
the green LED will turn on.  
 
To  change  sensitivity  levels,  press  the  SENS  once  for  HI 
sensitivity  (red  LED  will  turn  on)  and  again  for  LO  sensitivity 
(yellow LED will turn on). 
 
Leak Test Vial 
 
The leak detector comes with a Leak Test Vial that allows the 
user to make sure the detector is performing properly.  To test: 
 
1.  Remove the Plastic Seal Cap on the top of the Leak Test 
Vial  by  pulling  it  off  (see  fig.  below).  Also,  remove  and 
discard the circular Leak Test Cap Seal.  
 
2.  Turn  on  the  leak  detector  and  allow  the  unit  to  complete 
the warm up cycle.  
 
3.  Place the sensor close to the small hole in the top of the 
Leak  Test  Vial.  The  beep  rate  should  increase  and  the 
Digital Leak Size Indicator should display a number from 
4-6 indicating that the sensor and electronics are working 
properly.   
 
 
 
 
 
 
 
 
 
 
NOTE:  Remember  to  replace  the  Plastic  Seal  Cap  after  the  leak 
test  is  completed.  Replace  the  Leak  Test  Vial  when  the  green 
media color is no longer visible and the leak media has evaporated. 
Remove  the  threaded  cap  on  the  Vile  to  confirm  the  status  of  the 
leak  test  media.  After  the  leak  test  media  has  evaporated,  it  is 
normal for there to be a green film on the wall of the Leak Test Vial.  
 
Remove the Plastic Seal 
Cap to Test the Leak 
Detector 
Leak Test Cap Seal  
Leak Test Vial 
Maintenance 
 
 
 
 
 
 
 
 
 
 
 
Polarity Mark 
Filter 
Keyway alignment 
Pull straight out (do not 
twist) to remove sensor 
Unscrew tip to 
replace filter 
 
Push straight on (do not 
twist) to install sensor 
Batteries: 
 
Install  Batteries:  Remove  screw  located  at  rear  end  of  unit  and 
pull down hinged battery door to open as shown.  Always insert all 
four batteries into the battery compartment in the same direction.  
Note  polarity  mark  on  the  inside  of  the  battery  door  for  proper 
battery orientation.  
 
Sensor: 
 
Replace  Filter:  Unscrew  sensor  tip  as  shown  to  replace  filter.  
Replace  filter  whenever  it  becomes  visibly  dirty  or  every  2  to  3 
months depending on use. 
 
Replace  Sensor:  Remove  sensor  by  pulling  out  of  socket.  Install 
the  new  sensor  by  aligning  the  Keyway  notch  in  sensor  cover  with 
the raised keyway on sensor socket holder (see figure below).  
 
Note:  Do  not  force  sensor  into  socket.    Misalignment  can 
damage the sensor pins. 
 
IMPORTANT:  The  instrument’s  software  is  designed  to  alert  the 
user  if  the  sensor  is  dislodged  or  defective.  If  the  sensor  is  not 
fully  inserted  into  the  six-pin  socket,  or  if  it  is  defective,  the 
instrument  will  not  come  out  of  the  “Warm  Up”  mode  for  proper 
operation when the power button is turned on. Additionally, if the 
instrument  becomes  unstable  during  its  operation,  it  is  an 
indication that the sensor may be defective.