ArtDio IPE 1000 用户手册

下载
页码 91
 
 43
Category Entry Description 
Data 
Type
Range 
Transit 
Call 
Function 
Enable or disable Transit Calls 
RW  Enable/Disable 
Transit 
Call 
Waiting 
Time 
The timer for sending a warning 
tone to the caller while a transit 
call is taking place.  
RW (1~60) 
min 
(Default=3) 
CDR 
Report 
Enables or disables CDR report 
output
6
RW Enable/Disable 
Greeting 
Mode 
There is no message recorded by 
default.  
You can record your own greeting 
message and select how many 
times to play the recording.
7
 
RW  Default(Not to 
play), Play 
Recording 
Once, twice, 3, 
4, 5, 6, 7, 8 
times 
Auto 
Attendant 
Shows whether or not your PBX 
is equipped with the Auto 
Attendant function 
RW Provided/Not 
Provided 
Slave 
UDP Port 
No. 
The UDP port number which 
carries Call Control signaling 
from this slave devices with other 
gateways 
RW 0~65535 
(default value 
is 2000
Master 
UDP Port 
No. 
The UDP port number which 
carries Port Information signals to 
the master device 
RW 0~65535 
(default value 
is 2000
Configuration 
RTP Base 
Port No. 
The Base RTP port number which 
carries voice streaming data 
between gateways 
RW 0~65535 
(must be even) 
Note  2 The master UDP port number on slave devices should be the same as the definition on the master 
device. But the slave UDP port number for each slave may be different for each device. 
The configurations of the UDP port number and the RTP port number are related to the firewall settings of 
your network (refer to chapter 6 Firewall Configuration). Please consult your network administrator before 
making any changes. 
                                                      
6
 CDR report works only on models that are equipped with the extra RS-232 CDR output interface 
7
 You can use the Phone Set Interface to configure the Skip Greeting Access Code (item code 30) to specify the access code while trying to 
bypass the greeting message recorded in the device.