After cleaning, apply a thin coat of grease or petroleum 
jelly to terminals and cable ends, to retard corrosion. 
Reinstall battery.
To charge battery remove battery from riding mower, 
remove vents and charge at a rate of 1.2 amps for 10 
hours on a fully discharged battery.
IMPORTANT: Charging at a higher rate will damage 
battery.
Battery
When charging battery remove it from the unit first.
Battery Electrolyte First Aid
Follow First Aid directions for contact with battery fluid.
• External Contact: Flush with water.
• Eyes: Flush with water for at least 15 minutes and 
get medical attention immediately!
• Internal Contact: Drink large quantities of water. 
Follow with Milk of Magnesia, beaten egg or 
vegetable oil. Get medical attention immediately!
IMPORTANT: In case of internal contact, DO NOT 
induce vomiting.
Battery Charger
Under normal conditions the engine alternator will have 
no problem keeping the battery charged. When unit 
has set for an extended period of time without 
operating and the battery has been completely 
discharged, a battery charger will be required for 
recharging.
Before using a charger, an attempt can be made to 
recharge the battery using the engine alternator by 
jump starting the unit and allowing the to engine run.
Jump Starting
Jump starting, battery charging or replacement is 
required when the starter motor will not crank the 
engine.
DO NOT charge a frozen battery. Let the battery thaw 
out before putting on a charger.
To jump start battery:
1. Ensure battery is not frozen. If the fluid is frozen, 
remove battery from unit and allow it to thaw before 
charging.
2. The unit used for jump starting should have a 12 
volt battery with at least 500 cold cranking 
amperes, and a negatively grounded system.
3. Connect the positive (+) jumper cable to the 
positive terminal of the discharged battery.
4. Connect the other end of the same jumper cable to 
the positive (+) terminal of the booster battery.
5. Connect one end of the second jumper cable to the 
negative (-) terminal of the booster battery.
6. Make the final jumper cable connection to the 
engine block or the furthest ground point away 
from the discharged battery.
7. Start the engine.
8. Remove jumper cables in the reverse order of their 
connection. Remove cable from ground point, the 
negative (-) terminal of the booster battery, the 
positive (+) terminal of the booster battery, and 
then the positive (+) terminal of the discharged 
battery.
IMPORTANT: DO NOT fast charge. Charging at higher 
rate will damage or destroy battery.
CAUTION: Connect positive (+) cable first, 
negative (-) cable last.
WARNING: When charging battery, remove it 
from unit and make certain that you connect 
positive (+) lead of charger to positive (+) 
terminal and negative (-) lead to negative (-) 
terminal. Reverse connections can cause 
sparks and potential unsafe conditions.
WARNING: ELECTRIC SHOCK may result in 
injury and/or damage to unit.
DO NOT allow object to come into contact 
with both terminals at the same time. 
REVERSE CONNECTIONS may result in 
sparks which can cause death or serious 
injury. ALWAYS connect positive (+) lead of 
charger to positive (+) terminal, and negative 
(-) lead to negative (-) terminal.
ALWAYS connect positive (+) cable FIRST, 
and negative (-) cable SECOND.
DO NOT TIP any battery beyond 45
o
 angle in 
any direction.
ALWAYS KEEP BATTERIES OUT OF 
REACH of children.
WARNING: FROZEN BATTERIES CAN 
EXPLODE and result in death or serious 
injury.
WARNING: UNIT MOVEMENT can result in 
death or serious injury. NEVER jump start unit 
directly to the starter or starter solenoid. Unit 
can move forward or backward and injure the 
person jump starting unit.
CAUTION: REVERSE CONNECTIONS may 
result in sparks which may result in injury. 
ALWAYS connect/disconnect cables in proper 