Guide to installation and operation
21
The Alarm Setup Window
Problems detected by the VLD-1002-MD card are transmitted as alarms                 
to the card’s LED, to the Dashboard interface, and to the optional SNMP 
monitoring. The problems detected can be reported to the user as minor 
alarms or critical alarms.
The Alarm Setup window allows the user to set the alarm level at which 
many types of errors will be reported to the LEDs or to Dashboard, 
independently for channel 1 and 2, for the reference signal and for the 
license key detection. The alarm signals can also be disabled.
Minor: When the alarm level for a specific type or error is set to minor, 
the card’s LED will report the problem with a yellow light and Dashboard 
with a yellow circle next to an error message describing the problem.
Critical: When the alarm level for a specific type or error is set to critical, 
the card’s LED will report the problem with a red light and Dashboard with 
a red circle next to an error message describing the problem.
Carrier and video detection errors on input 1 are always reported as 
critical and cannot be set otherwise.
The  Alarm Setup settings are automatically saved to memory and are 
recalled after a power-up.
Alarms reported to card’s LED
Alarms reported to Dashboard
Input 1(DS2)
Card status (DS1)
Input 2 (DS3)
Not used (DS4)
Not used (DS5)
Card Reference (DS6)