Short Form Report
The Short Form report includes summary information about the current test. This information fits on one page.
The following is a sample short form report of a Fluctuating Current Harmonics test:
                 IEC 1000-3-2/EN 61000-3-2  Fluctuating Current Harmonics Test
                                Date Performed:  06/15/97
              Test Executed By:  A.C. Testright
                  Company Name:  True Test Laboratories
          Device Under Test ID:  Model 12345 Modular Power Supply
                       Test ID:  00123
Approved by: QA
Signature:________________________________________________________ Date:__________________
Final Test Result:  FAIL
Settings and Test Conditions Compliant to the Standard:  Yes
Test Equipment Used:
       Agilent 6842A Harmonic/Flicker Test System with serial number 3440A-00101
       Agilent 14761A HFTS software Version:  A.00.05
       Date Last Calibrated: June 6, 1997
Test Equipment Settings:
------------------------
Line Voltage:  230.00 V
Current Measurement Range:  High
Line Frequency:  50 Hz
Measurement Delay:  10.0 seconds
Device Class:  D
Fluctuating Harmonics Test Duration:  2.00 minutes
Class Determination Pre-test Duration:  10.00 seconds
Overrides:
----------
Test Limit Source (Power Measurements/Statistics): Maximum
Power Overrides: None
Test Limit Overrides: None
Pre-test Results for Class Determination:
-----------------------------------------
Percent in Envelope:  100.0%
Fundamental Current:  1.343 A
Class D Equipment?:  Yes
Real Power:  148.8 W
Voltage THD Out-of-Specification?:  No
Power Factor: 0.387
Maximum Power:  148.8 W
Mean Power:  146.7 W
Total Number of Failures:
Total Number of Errors:
-------------------------
-------------------------
4505 Failures
None