4.1 Local Programming with PC-Link
Follow the steps below in the sequence indicated to set up local programming using DLS:
New Installations (Refer to section 1.1 Installation on page 2)
1. Connect the AC Wiring before mounting the back plate.
2. Secure the front cover to the backplate
3. Connect the PC-Link cable between the Computer with DLS Software installed and the header pins on the alarm panel to be programmed.
 
4. When programming has been completed remove the PC-Link cable and the front cover from the backplate
5. Complete the installation
Existing Installations (Refer to section 1.1 Installation on page 2)
1. Remove the front plate and place it into the third hand – keeping the battery connected. See Figure 3, Third Hand 
2. Place the PC-Link cable on the header pins and the downloading session will occur. 
3. Upon completion of the session remove the PC-Link cable. 
4. Remove the front plate from the third hand and secure it to the back plate.
4.2 Remote Programming (via telephone line)
Refer to Section “[401] Downloading Options” on page 25 and page 40 for details. 
In a new installation the backup battery requires 24 Hrs. charging. 
AC Power is required for PC-Link Programming until battery is charged.
Connecting the DLS PC to the system will automatically initiate the connection.
Figure 3, Third Hand
AC Power must be present for the Alarm system to answer Incoming calls from DLS