DSCover Satellite Products Home Security System SCW904x 用户手册

下载
页码 64
Appendix A: Reporting Code Formats
51
[347]
Installer Lead In
Installer’s mode has been entered
MA/R
(6)27
LB-00
[347]
Installer Lead Out
Installer’s mode has been exited
MA/R
(6)28
LS-00
[348]
Walk Test End
End of test
T
(6) A7
TE-00
[348]
Walk Test Begin
Beginning of test
T
(6) A7
TS-00
[348]
Periodic Test
Periodic system test transmission 
T
(6) A2
RP-00
[348]
System Test
[*][6] bell/communications test
T
(6) A1
RX-00
[601]-[604]
Closings
System armed (user 33-95 indicated)
O/C
(4) A1
CL-UU
[605]-[608]
Openings
System disarmed (user 33-95 indicated)
O/C
(4) A1
OP-UU
*
A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
**  
UU = user number (user01-16,40); ZZ = zone number (01-34)
***
Use the “Fail to close” event code [(4)54] to report closing or activity delinquency. Ensure the central station is aware that this code is used.
****
Zones are panic pendants are identified, wireless keys can be identified for openings and closings.
Section #
Reporting Code
Code Sent When...
Dialer 
Direction*
Automatic 
Contact ID 
Codes
SIA Auto
Rep Codes**
Contact ID Zone Alarm/Restoral Event Codes
(as per SIA DCS: ‘Contact ID’ 01-1999):
Program any of these codes for zone alarms/restorals when using the
standard (non-automatic) Contact ID reporting format.
SIA Format Automatic Zone Alarm/Restoral Codes
Medical Alarms 
(1)34 Entry / Exit
(1)AA Medical
(1)35 Day / Night
(1)A1 Pendant Transmitter
(1)36 Outdoor
(1)A2 Fail to Report In
(1)37 Tamper
Fire Alarms
(1)38 Near Alarm
(1)1A Fire Alarm
General Alarms
(1)11 Smoke
(1)4A General Alarm
(1)12 Combustion
(1)43 Exp. module failure
(1)13 Water Flow
(1)44 Sensor tamper
(1)14 Heat
(1)45 Module Tamper
(1)15 Pull Station
(1)4A Cross Zone Police Code
(1)16 Duct
24 Hour Non-Burglary
(1)17 Flame
(1)5A 24 Hour non-Burg
(1)18 Near Alarm
(1)51 Gas detected
Panic Alarms
(1)52 Refrigeration
(1)2A Panic
(1)53 Loss of Heat
(1)21 Duress
(1)54 Water Leakage
(1)22 Silent
(1)55 Foil Break
(1)23 Audible 
(1)56 Day Trouble
Burglar Alarms
(1)57 Low bottled Gas level
(1)3A Burglary
(1)58 High Temp
(1)31 Perimeter
(1)59 Low Temp
(1)32 Interior
(1)61 Loss of Air Flow
(1)33 24 Hour
Zone Definition
SIA Auto Rep 
Codes*
Contact ID Auto 
Rep Codes*
Delay 1
BA-ZZ/BH-ZZ
(1) 3A
Delay 2
BA-ZZ/BH-ZZ
(1) 3A
Instant
BA-ZZ/BH-ZZ
(1) 3A
Interior
BA-ZZ/BH-ZZ
(1) 3A
Interior Stay/Away
BA-ZZ/BH-ZZ
(1) 3A
Delay Stay/Away
BA-ZZ/BH-ZZ
(1) 3A
24-Hr. Supervisory
US-ZZ/UR-ZZ
(1) 5A
24-Hr. Supervisory Buzzer
UA-ZZ/UH-ZZ
(1) 5A
24-Hr. Burg
BA-ZZ/BH-ZZ
(1) 3A
24-Hr. Gas
GA-ZZ/GH-ZZ
(1) 51
24-Hr. Heat
KA-ZZ/KH-ZZ
(1) 58
24-Hr. Medical
MA-ZZ/MH-ZZ
(1) AA
24-Hr. Panic
PA-ZZ/PH-ZZ
(1) 2A
24-Hr. Emergency (non-medical)
QA-ZZ/QH-ZZ
(1) A1
24-Hr. Water
WA-ZZ/WH-ZZ
(1) 54
24-Hr. Freeze
ZA-ZZ/ZH-ZZ
(1) 59
Interior Delay
BA-ZZ/BH-ZZ
(1) 3A
Instant Stay/Away
BA-ZZ/BH-ZZ
(1) 3A
24-Hr. Non-latching Tamper
UA-ZZ/UH-ZZ
(1) 4A
Night Zone
BA-ZZ/BH-ZZ
(1) 3A
Delayed 24-Hr. Fire (Wireless)
FA-ZZ/FH-ZZ
(1) 1A
Standard 24-Hr. Fire (Wireless)
FA-ZZ/FH-ZZ
(1) 1A
24-Hr. Auto Verified Fire (Wireless)
FA-ZZ/FH-ZZ
(1) 1A
* ZZ = zones 01-34
WWW.DIYALARMFORUM.COM