DKS Enterprises 9310 用户手册

下载
页码 55
1.2 Concrete 
Pad 
The model 9310 vehicular gate operator is designed to be mounted on a concrete pad.   
 
1.  Construct a form for the mounting pad according to the specifications shown below. Note 
that the pad for the 1 HP operator extends an additional 6 inches to the right to 
accommodate the larger cover
.  Be sure to level the top edge of the form and that the 
top of the form is a minimum of four (4) inches above ground level.  We suggest that you 
contact the local building department to determine the required depth of the pad since 
soil conditions and code requirements vary from city to city. 
2.  Set conduits, reinforcing bars and/or wire mesh if required. If the slide gate operator 
has a battery backup system, then conduits must be located in the area shown.  
The number of conduits is determined by the application requirements. We suggest using 
a minimum of four (4) conduits.  1-High voltage power lines; 2-Low voltage control lines; 
3-Loop lead-in wires (open loop); 4-Loop lead-in wires (reverse loops).  See SECTION 2
3.  Mix the concrete according to the manufacturers instructions. Pour the mixture into the 
form and tamp. Level and finish the surface after pouring is complete. Do not set anchor 
bolts in the concrete.  Sleeve anchors should be used to secure the operator to the pad. 
This allows greater flexibility in positioning the operator on the pad. 
4.  Allow the pad to cure for 48 hours before removing the forms or mounting the operator. 
 
 
26.5 ½ hp
18
.5
4
3 3
/4
Mi
n
GATE
1
6
G
A
T
E
 BR
KT
CONDUIT
AREA FOR
UNITS WITH
BATTERY B/U
4" Minimum Above
Ground Level
5
6.
5
Depth of pad determined by soil
conditions and local code.
4
7
18.5
14
6
32.5 1 hp
Cover 1 HP
Cover 1/2 HP
10
 
14