Appendix B
83
APPENDIX B: CLIPPER BOARD E-POINT JUMPERS
E0: Forced Reset Control
E-Point
Description
Default
E0
Factory use only; the board will not operate with E0 installed.
Not
Installed
E3: Re-Initialization On Reset Control
E-Point
Description
Default
E3
Remove Jumper for normal operation.
Jump 1-2 for re-initialization on power-up.
Not
Installed
E4: Watchdog Disable Jumper
E-Point
Description
Default
E4
Remove Jumper for normal operation.
Install Jumper to disable watchdog timer.
Not
Installed
E5: Reserved for factory use only
Revision 102 or newer
E Point
Description
Default
E5
3
2
1
For factory use only; the board will not communicate via
Ethernet or USB if jumper E5 is installed.
Ethernet or USB if jumper E5 is installed.
Not
Installed
Revision 101 or older
E Point
Description
Default
E5
For factory use only; the board will not communicate via
Ethernet unless Jumper is installed on pins 1 to 2.
Ethernet unless Jumper is installed on pins 1 to 2.
Jumpered
1-2