Operations
Calibrate the Printer
48
14068L-001 Rev. A
X-Plus II User Guide
1/11/07
Calibrate the Printer
Calibrate the printer when it is first put into service. Calibration allows the printer to establish 
the proper settings for the specific media and ribbon used in your application. You may 
calibrate the printer at other times as needed
 shows the different methods for 
calibration.
Table 7 • Types of Calibration
Type of Calibration
Description
When/How It Occurs
Auto-calibration 
The printer automatically sets the 
value it detects for the spaces between 
labels.
Occurs at the following times:
• When the printer is first turned on if 
CALIBRATION is selected for 
MEDIA
 
POWER
 
UP
• When the printer feeds media after 
the printhead is closed if 
CALIBRATION is selected for 
HEAD CLOSE
 (see 
• As part of both the sensor profile 
and media and ribbon sensor 
calibration procedures.
Long (Standard) 
Calibration 
The printer does the following:
• feeds media and ribbon
• sets the values it detects for media 
length, media type (continuous or 
non-continuous), and print mode 
(thermal transfer or direct thermal)
• updates the sensor values
To perform a long calibration, do one 
of the following:
• Press 
PAUSE
 on the control panel 
to pause the printer, and then press 
CALIBRATE
.
• Select CALIBRATION for the 
MEDIA
 
POWER
 
UP
 or 
HEAD
 
CLOSE
 parameter (see 
Short Calibration
The printer calibrates using the 
current sensor values rather than 
detecting the spaces between labels 
and resetting the sensors. This 
calibration sequence uses fewer labels 
than the long calibration sequence, but 
it is less reliable because the values 
that are stored in the sensors could be 
incorrect.
Select SHORT CAL for the 
MEDIA
 
POWER
 
UP
 or 
HEAD
 
CLOSE
 
parameter (see 
 or