Operations
Adjust Media Sensors
1/11/07
X-Plus II User Guide
14068L-001 Rev. A
5.
Tighten the adjustment screw to secure the upper media sensor.
Upper Media Sensor—Outside Half of Media
To adjust the upper media sensor for the outside half of the media, complete 
these steps:
1.
Remove the ribbon (if ribbon is used).
2.
Locate the upper media sensor. The upper media sensor eye is directly 
below the adjustment screw head. 
3.
Using a Phillips-head screwdriver, remove the upper media sensor adjustment screw.
4.
Lift the upper media sensor assembly from the slot, and move it and the wire cover to the 
outside slot. Carefully pull the wires through the cable tie. You may need to set aside the 
sensor wire cover if the adjustment is too far to the outside.
5.
Replace and slightly tighten the adjustment screw.
6.
Slide the upper media sensor along the slot to the desired position (for non-continuous 
media with a notch or hole in the media, the sensor must be directly above the notch or 
hole).
7.
Tighten the adjustment screw.
8.
Make sure that the wires are routed back into the groove of the media sensor bracket.