Red LED - Strobe 
If this checkbox is checked, the red 
LED output of a receiver or the strobe 
output of an alert unit is turned on if 
On is clicked, or off if Off is 
clicked. If this checkbox is not 
checked, the state of this output does 
not change. 
Off 
When clicked, the checked Horn-Siren
Green LED, and Red LED - Strobe outputs 
are turned off for the selected point 
on the selected transponder. If the 
output does not change, click On and 
then click Off again. 
On 
When clicked, the checked Horn-Siren
Green LED and Red LED - Strobe outputs 
are turned on for the selected point on 
the selected transponder. If the output 
does not change, click Off and then 
click On again. 
Ambient 
The Ambient value is shown above Auto 
Advance
 displaying the current ambient 
level at the receiver. To get an 
updated ambient reading, select the 
point, click the Transmit button, and 
click the Ambient button. 
RF Micro Version 
The receiver’s RF micro revision level 
is shown below Auto Advance. To get an 
updated reading, click the Revision 
button. 
Antenna 
Normally, a receiver automatically 
switches between its diversity antennas 
during normal operation (leave the 
default selection on a working system 
at this setting). The receiver can be 
forced to use only the left or right 
antenna, or always switch by selecting 
the appropriate setting and clicking 
the Antenna button. 
Ant Map 
Clicking Ant Map causes the system to 
interrogate the current antenna 
switching settings of all receivers on 
this transponder. 
Transmit 
Clicking Transmit causes this receiver 
to send one test transmission. 
Reset Point 
Clicking Reset Point causes the 
microprocessors on this point to reset 
as if they were just powered up. A 
receiver should not be reset in a 
working system, as it can cause 
receptions to be lost. 
Ambient 
Clicking Ambient causes the system to 
interrogate the current ambient levels 
of all receivers on this transponder. 
Revision 
Clicking Revision causes the system to 
interrogate the RF micro revision 
levels of all receivers on this 
transponder. 
Jamming 
A receiver monitors the ambient level 
during normal operation. If the ambient 
level rises above the jamming setting 
and jamming trouble, it is reported to 
the central console. The receiver’s 
jamming level can be adjusted by 
selecting the appropriate setting 
(shown in hexadecimal levels) and 
clicking the Jamming button. 
Jam Map 
Clicking Jam Map causes the system to 
interrogate the jamming setting levels 
of all receivers on this transponder. 
3.3.14 
Receiver Test Screen 
Use this screen to set up and monitor 
four receivers and listen to one 
receiver transmitting with its Buddy 
Check Transmitter. Normally, the 
function is for engineering evaluation 
of new transmitter and receiver 
designs, but it can be used to test 
receiver boards and locations in a 
working system. 
Figure 499: Receiver Test Screen