Bosch Appliances DVR MVM-BVRM 用户手册

下载
页码 42
iSCSI System Access tab
Main window > Devices tab > Expand 
 > Expand 
 Storage Systems > Desired iSCSI
device: 
 > iSCSI System Access tab
Configuration password
Enter the password that enables the VRM system to access the iSCSI storage system for
configuration purposes.
SNMP IP address
If the RAID system has its own port for SNMP requests, enter the relevant SNMP IP address
here.
Default Configuration tab
Main window > Devices tab > Expand 
 > Expand 
 Storage Systems > Desired iSCSI
device: 
 > Default Configuration tab
Only displayed if the device is an iSCSI storage system supported by Bosch, for example
NetApp.
Capacity [MB]
Information on the total capacity of the storage system.
Number of LUNs
You can change the number of LUNs.
!
Caution!
If you change the number of LUNs, the entire iSCSI system is reorganized and any sequences
saved on the system are lost.
Therefore, before making changes, check the recordings and back up any important sequen-
ces.
Initialization status (%)
Additional information is displayed during initialization. When initialization is complete
(100%), you will also have the opportunity to delete all LUNs again.
Note: On NetApp storage systems, it can take several hours before LUNs are fully deleted.
During that time, the total capacity of newly created LUNs can be reduced. You can only
create new LUNs with full capacity after the old LUNs have been completely deleted.
RAID-DP (reliability focused)
This option is only displayed for NetApp DSA-N2B20.
Activate this option if you do not wish to use the specified RAID type RAID-4, but would prefer
to use the more reliable RAID type RAID-DP.
Load Balancing tab
Main window > Devices tab > Expand 
 > Expand 
 Storage Systems > Desired iSCSI
device: 
 > Load Balancing tab
Set the upper limits for the permitted bit rate and the number of simultaneous iSCSI
connections for each iSCSI system. If these limits are exceeded, data is no longer being
written to the iSCSI system and is lost.
For supported systems (for example Bosch RAID, NetApp, DLA), use the default values. For
another device see the documentation of this device. Start testing with small values.
12.5
12.6
 
12.7
Video Recording Manager
User interface | en
29
Bosch Sicherheitssysteme GmbH
Software Manual
2012.05 | v1 | DOC