Bosch 2000 用户手册

下载
页码 72
2000 Series | Program Entry Guide | 2.0 
Phone 
EN | 8 
 
 
Bosch Security Systems | 7/05 | 35114F 
 
5 Fire Route 
Default: 
Local
 
Selection: 
Local, Phone 1 only, Phone 2 only, 
Both
 
Local 0 
Phone 1 only 
Phone 2 only 
Both 3 
Reports: Fire Alarm Reports from points or ABC 
keys. 
6 Non-Fire Route 
Default: 
Local
 
Selection: 
Local, Phone 1 only, Phone 2 only, 
Both
 
Local 0 
Phone 1 only 
Phone 2 only 
Both 3 
Reports:  
 
Non-Fire Alarm Reports from points or ABC 
keys 
 
Point Tamper Alarms 
 
Point Missing Alarms. 
7 Pt Trbl Route 
Default: 
Local
 
Selection: 
Local, Phone 1 only, Phone 2 only, 
Both
 
Local 0 
Phone 1 only 
Phone 2 only 
Both 3 
Reports:  
 
Trouble, Missing, Missing RF, Low Battery RF, 
Bypass, or Swinger Bypass Reports from, Fire 
and Non-fire points combined. 
 
Point Tamper Troubles. 
8 Restoral Route 
Default: 
Local
 
Selection: 
Local, Phone 1 only, Phone 2 only, 
Both
 
Local 0 
Phone 1 only 
Phone 2 only 
Both 3 
Reports:  
 
Restoral Reports from Fire and Non-Fire points 
combined 
 
RF Battery Restorals 
 
Point Tamper Restorals. 
9 Closing Route 
Default: 
Local
 
Selection: 
Local, Phone 1 only, Phone 2 only, 
Both
 
Local 0 
Phone 1 only 
Phone 2 only 
Both 3 
Reports: Closing Reports 
10 Opening Route 
Default: 
Local
 
Selection: 
Local, Phone 1 only, Phone 2 only, 
Both
 
Local 0 
Phone 1 only 
Phone 2 only 
Both 3 
Reports: Opening Reports